The Effect of Changes in Stimulus Level on Electrically Evoked Cortical Auditory Potentials
- 1 June 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (3) , 320-329
Abstract
Objectives: The purpose of this study was to determine whether the electrically evoked acoustic change complex (EACC) could be used to assess sensitivity to changes in stimulus level in cochlear implant (CI) recipients and to investigate the relationship between EACC amplitude and rate of growth of the N1-P2 onset response with increases in stimulus level. Design: Twelve postlingually deafened adults using Nucleus CI24 CIs participated in this study. Nucleus Implant Communicator (NIC) routines were used to bypass the speech processor and to control the stimulation of the implant directly. The stimulus consisted of an 800 msec burst of a 1000 pps biphasic pulse train. A change in the stimulus level was introduced 400 msec after stimulus onset. Band-pass filtering (1 to 100 Hz) was used to minimize stimulus artifact. Four to six recordings of 50 sweeps were obtained for each condition, and averaged responses were analyzed in the time domain using standard peak picking procedures. Results: Cortical auditory change potentials were recorded from CI users in response to both increases and decreases in stimulation level. The amplitude of the EACC was found to be dependent on the magnitude of the stimulus change. Increases in stimulus level elicited more robust EACC responses than decreases in stimulus level. Also, EACC amplitudes were significantly correlated with the slope of the growth of the onset response. Conclusions: This work describes the effect of change in stimulus level on electrically evoked auditory change potentials in CI users. The amplitude of the EACC was found to be related both to the magnitude of the stimulus change introduced and to the rate of growth of the N1-P2 onset response. To the extent that the EACC reflects processing of stimulus change, it could potentially be a valuable tool for assessing neural processing of the kinds of stimulation patterns produced by a CI. Further studies are needed, however, to determine the relationships between the EACC and psychophysical measures of intensity discrimination in CI recipients.Keywords
This publication has 31 references indexed in Scilit:
- The Electrically Evoked Auditory Change Complex: Preliminary Results from Nucleus Cochlear Implant UsersEar & Hearing, 2008
- Cortical Evoked Response to Gaps in Noise: Within-Channel and Across-Channel ConditionsEar & Hearing, 2007
- Electrophysiologic correlates of intensity discrimination in cortical evoked potentials of younger and older adultsHearing Research, 2007
- Electrophysiological and speech perception measures of auditory processing in experienced adult cochlear implant usersClinical Neurophysiology, 2005
- Neurophysiology of Cochlear Implant Users II: Comparison Among Speech Perception, Dynamic Range, and Physiological MeasuresEar & Hearing, 2002
- A Sensitive Period for the Development of the Central Auditory System in Children with Cochlear Implants: Implications for Age of ImplantationEar & Hearing, 2002
- Evaluation of cochlear implant benefit with auditory cortical evoked potentials: Evaluación de los beneficios del implante coclear por medio de potenciales evocados auditivos corticalesInternational Journal of Audiology, 2002
- Frequency and intensity discrimination measured in a maximum-likelihood procedure from young and aged normal-hearing subjectsThe Journal of the Acoustical Society of America, 1998
- The Relation between Electric Auditory Brain Stem and Cognitive Responses and Speech Perception in Cochlear Implant UsersActa Oto-Laryngologica, 1996
- The N1 Wave of the Human Electric and Magnetic Response to Sound: A Review and an Analysis of the Component StructurePsychophysiology, 1987