The diagnostic accuracy of high b-value diffusion- and T2-weighted imaging for the detection of prostate cancer: a meta-analysis
Open Access
- 24 November 2017
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 43 (7) , 1787-1797
Abstract
Purpose This study aims to investigate the role of diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) in combination for the detection of prostate cancer, specifically assessing the role of high b-values (> 1000 s/mm2), with a systematic review and meta-analysis of the existing published data. Methods The electronic databases MEDLINE, EMBASE, and OpenSIGLE were searched between inception and September 1, 2017. Eligible studies were those that reported the sensitivity and specificity of DWI and T2WI for the diagnosis of prostate cancer by visual assessment using a histopathologic reference standard. The QUADAS-2 critical appraisal tool was used to assess the quality of included studies. A meta-analysis with pooling of sensitivity, specificity, likelihood, and diagnostic odds ratios was undertaken, and a summary receiver-operating characteristics (sROC) curve was constructed. Predetermined subgroup analysis was also performed. Results Thirty-three studies were included in the final analysis, evaluating 2949 patients. The pooled sensitivity and specificity were 0.69 (95% CI 0.68–0.69) and 0.84 (95% CI 0.83–0.85), respectively, and the sROC AUC was 0.84 (95% CI 0.81–0.87). Subgroup analysis showed significantly better sensitivity with high b-values (> 1000 s/mm2). There was high statistical heterogeneity between studies. Conclusion The diagnostic accuracy of combined DWI and T2WI is good with high b-values (> 1000 s/mm2) seeming to improve overall sensitivity while maintaining specificity. However, further large-scale studies specifically looking at b-value choice are required before a categorical recommendation can be made.Keywords
This publication has 56 references indexed in Scilit:
- Diffusion‐weighted imaging of the prostate: Comparison of b1000 and b2000 image sets for index lesion detectionJournal of Magnetic Resonance Imaging, 2013
- Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR ImagingRadiology, 2013
- Diagnostic accuracy of ultra-high-b-value 3.0-T diffusion-weighted MR imaging for detection of prostate cancerClinical Imaging, 2012
- Detectability of low and intermediate or high risk prostate cancer with combined T2-weighted and diffusion-weighted MRIEuropean Radiology, 2012
- ESUR prostate MR guidelines 2012European Radiology, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Diffusion-weighted Endorectal MR Imaging at 3 T for Prostate Cancer: Tumor Detection and Assessment of AggressivenessRadiology, 2011
- Prostate cancer detection with magnetic resonance imaging: is dynamic contrast-enhanced imaging necessary in addition to diffusion-weighted imaging?Diagnostic and Interventional Radiology, 2010
- Prostate Cancer: Apparent Diffusion Coefficient Map with T2-weighted Images for Detection—A Multireader StudyRadiology, 2009
- Usefulness of apparent diffusion coefficient map in diagnosing prostate carcinoma: Correlation with stepwise histopathologyJournal of Magnetic Resonance Imaging, 2007