Sensing of Stimulus Artifact Suppressed Signals From Electrode Interfaces
- 3 February 2015
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (7) , 3734-3742
Abstract
Stimulus artifacts inhibit reliable acquisition of biological evoked potentials for several milliseconds if an electrode contact is utilized for both electrical stimulation and recording purposes. This hinders the measurement of evoked short-latency biological responses, which is otherwise elicited by stimulation in implantable prosthetic devices. We present an improved stimulus artifact suppression scheme using two electrode simultaneous stimulation and differential readout using high-gain amplifiers. Substantial reduction of artifact duration has been shown possible through the common-mode rejection property of an instrumentation amplifier for electrode interfaces. The performance of this method depends on good matching of electrode-electrolyte interface properties of the chosen electrode pair. A novel calibration algorithm has been developed that helps in artificial matching of impedance and thereby achieves the required performance in artifact suppression. Stimulus artifact duration has been reduced down to 50 μs from the stimulation-cum-recording electrodes, which is ~6× improvement over the present state of the art. The system is characterized with emulated resistor-capacitor loads and a variety of in-vitro metal electrodes dipped in saline environment. The proposed method is going to be useful for closed-loop electrical stimulation and recording studies, such as bidirectional neural prosthesis of retina, cochlea, brain, and spinal cord.Keywords
Funding Information
- National Research Foundation Singapore Competitive Research Program Program (NRF-CRP10-2012-01)
- National University of Singapore, Singapore
- Agency for Science, Technology and Research
- Tata Consultancy Services
This publication has 28 references indexed in Scilit:
- Electrically evoked compound action potential artifact rejection by independent component analysis: Technique validationHearing Research, 2013
- A low-cost multielectrode system for data acquisition enabling real-time closed-loop processing with rapid recovery from stimulation artifactsFrontiers in Neuroengineering, 2009
- A novel stimulus artifact removal technique for high-rate electrical stimulationJournal of Neuroscience Methods, 2008
- Minimization of cochlear implant stimulus artifact in cortical auditory evoked potentialsClinical Neurophysiology, 2006
- A Closed-Loop Electrical Stimulation System for Cardiac Cell CulturesIEEE Transactions on Biomedical Engineering, 2005
- Spectral cancellation of microstimulation artifact for simultaneous neural recording in situIEEE Transactions on Biomedical Engineering, 2003
- A system for MEA-based multisite stimulationIEEE Transactions on Biomedical Engineering, 2003
- Nonlinear adaptive filtering of stimulus artifactIEEE Transactions on Biomedical Engineering, 2000
- Adaptive stimulus artifact reduction in noncortical somatosensory evoked potential studiesIEEE Transactions on Biomedical Engineering, 1998
- Suppression of stimulation artifacts from myoelectric-evoked potential recordingsIEEE Transactions on Biomedical Engineering, 1988