Characterization with X-rays of a Large-Area GEMPix Detector with Optical Readout for QA in Hadron Therapy
Authors:
- Andreia Maia OliveiraAOAndreia Maia Oliveira
- Hylke B. AkkermanHAHylke B. Akkerman
- Saverio BracciniSaverio Braccini
- Albert J. J. M. van BreemenABAlbert J. J. M. van Breemen
- Lucia Gallego ManzanoLMLucia Gallego Manzano
- Natalie HeracleousNHNatalie Heracleous
- Ilias KatsourasIKIlias Katsouras
- Johannes LeidnerJLJohannes Leidner
- Fabrizio MurtasFMFabrizio Murtas
- Bart PeetersBPBart Peeters
- Marco SilariMSMarco Silari
Open Access
- 13 July 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (14) , 6459
Abstract
Quality Assurance (QA) in hadron therapy is crucial to ensure safe and accurate dose delivery to patients. This can be achieved with fast, reliable and high-resolution detectors. In this paper, we present a novel solution that combines a triple Gas Electron Multiplier (GEM) and a highly pixelated readout based on a matrix of organic photodiodes fabricated on top of an oxide-based thin-film transistor backplane. The first LaGEMPix prototype with an active area of 60 × 80 mm2 was developed and characterized using low energy X-rays. The detector comprises a drift gap of 3.5 mm, a triple-GEM stack for electron amplification, and a readout featuring 480 × 640 pixels at a 126 µm pitch. Here, we describe the measurements and results in terms of spatial resolution for various experimental configurations. A comparison with GAFCHROMIC® films and the GEMPix detector used in the charge readout mode was performed to better understand the contribution to the spatial resolution from both the electron diffusion and the isotropic emission of photons. The measurements were compared to Monte Carlo simulations, using the FLUKA code. The simulation predictions are in good agreement with the GEMPix results. Future plans with respect to applications in hadron therapy are discussed.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (SFRH/BEST/142965/2018)
- ATTRACT project funded by the EC (under Grant Agreement 777222)
This publication has 39 references indexed in Scilit:
- The gas electron multiplier (GEM): Operating principles and applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Overview of the FLUKA codeAnnals of Nuclear Energy, 2015
- The FLUKA Code: Developments and Challenges for High Energy and Medical ApplicationsNuclear Data Sheets, 2014
- New radiation protection calibration facility at CERNRadiation Protection Dosimetry, 2013
- Characterizing the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulationsMedical Physics, 2013
- Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertaintiesPhysics in Medicine & Biology, 2013
- A GEM-based dose imaging detector with optical readout for proton radiotherapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- 2D dosimetry in a proton beam with a scintillating GEM detectorPhysics in Medicine & Biology, 2009
- Validity of the line‐pair bar‐pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imagingMedical Physics, 2007
- The GEM scintillation in He–CF4, Ar–CF4, Ar–TEA and Xe–TEA mixturesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003