Abstract
Object. In their pursuit of a better substitute for dura mater in neurosurgical procedures, the authors review their experience with GM972. Methods. A newly developed synthetic dural substitute composed of bioabsorbable polymers (GM972) was placed in 53 patients during neurosurgical procedures. The handling properties of the material, surgical wound features, and findings of hematological, computerized tomography, and/or magnetic resonance imaging examinations were evaluated. The average follow-up period was 35.5 months. The handling properties and biocompatibility of this new dural substitute were highly satisfactory, and no significant complication was observed. In patients who underwent a second surgery performed more than 18 months after the initial operation, this new dural substitute was found to have been replaced by autologous collagenous tissue. Because of its bioabsorbability, chronic foreign body reactions to this synthetic dural substitute were negligible. Conclusions. In this report the authors support the effectiveness and safety of this bioabsorbable artificial dural substitute that provides a reduced risk of transmission of latent infection.Keywords
This publication has 14 references indexed in Scilit:
- Clinical application of new bioabsorbable artificial dura mater: A preliminary reportJournal of Artificial Organs, 1998
- Complication of silastic dural substitute 20 years after dural plastySurgical Neurology, 1994
- An Unusual Complication of Silastic Dural Substitute: Case ReportNeurosurgery, 1990
- Inflammatory reaction to synthetic dural substituteJournal of Neurosurgery, 1989
- Neurosurgical use of human dura mater sterilized by gamma rays and stored in alcohol: long-term resultsJournal of Neurosurgery, 1987
- An unusual complication of Dura Film as a dural substituteJournal of Neurosurgery, 1984
- Recurrent subarachnoid bleeding in association with dural substituteJournal of Neurosurgery, 1984
- The role of neomembranes in formation of hematoma around Silastic dura substituteJournal of Neurosurgery, 1983
- Ethylene Oxide Sterilized, Freeze-Dried Dura Mater for the Repair of Pachymeningeal DefectsJournal of Neurosurgery, 1959
- Clinical Use of Freeze-Dried Human Dura MaterJournal of Neurosurgery, 1958