Background— Minimally invasive direct coronary artery bypass grafting (MIDCAB) is a well-established operative procedure. However, it is technically demanding and is therefore somewhat underused. We evaluated the clinical and angiographic outcome of patients undergoing a MIDCAB procedure with the Ventrica Magnetic Vascular Port (MVP®) system. Methods and Results— A Ventrica MVP® system was used in 10 of 11 selected MIDCAB patients. The system consists of 6 magnetic clips, with 3 clips forming a set. One magnetic clip set is positioned at the arteriotomy of the target artery and of the bypass graft using a preloaded delivery system. These ports then form an anastomosis by magnetic coupling. The mean age of the 10 patients (6 male) was 60.3±11.0 years. Three patients had an angiogram at the time of discharge and 8 returned for a 6-month angiogram. The total procedure time was 128.2±12.2 minutes. The mean anastomotic time was 199 seconds. The mean ischemic time during the anastomosis was 146±146 seconds. There were no in-hospital complications and no device-related adverse events. All 3 predischarge and all 8 6-month angiograms showed patent anastomoses. Conclusions— The magnetic vascular port facilitates the MIDCAB procedure significantly and reduces the ischemic time during the anastomosis. This minimally invasive procedure has the potential to be an alternative to percutaneous transluminal coronary angioplasty and stenting in proximal left anterior descending (LAD) stenosis. It may expand the acceptance of hybrid procedures in which a left internal mammary artery (LIMA)-to-LAD graft optimally supplies the anterior wall and the septum while the circumflex and right coronary artery may be treated interventionally.Keywords
This publication has 22 references indexed in Scilit:
- Total magnetic vascular coupling for arterial revascularizationThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Automated distal coronary bypass with a novel magnetic coupler (MVP system)The Journal of Thoracic and Cardiovascular Surgery, 2004
- Magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting: A multicenter trialThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Comparison of Stenting with Minimally Invasive Bypass Surgery for Stenosis of the Left Anterior Descending Coronary ArteryNew England Journal of Medicine, 2002
- Magnetic Compression Anastomosis for Benign Obstruction of the Common Bile DuctEndoscopy, 2001
- Is the GraftConnector a valid alternative to running suture in end-to-side coronary arteries anastomoses?The Annals of Thoracic Surgery, 2001
- Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro resultsThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Myocardial “hybrid” revascularisation with minimally invasive direct coronary artery bypass grafting combined with coronary angioplasty: preliminary results of a multicentre studyHeart, 2000
- Rare Earth Magnets in Orthodontics: An OverviewBritish Journal of Orthodontics, 1999
- A magnet system for urethral closure in femalesJournal of Biomedical Engineering, 1984