Comparison of Locking and Conventional Screws for Maintenance of Tibial Plateau Positioning and Biomechanical Stability After Locking Tibial Plateau Leveling Osteotomy Plate Fixation
- 1 June 2008
- journal article
- Published by Wiley in Veterinary Surgery
- Vol. 37 (4) , 357-365
Abstract
Objective—To compare locking screws with conventional screws inserted in the tibial plateau fragment for reduction and stability of the construct after tibial plateau leveling osteotomy (TPLO), using a locking TPLO plate.Study Design—Experimental biomechanical study.Animals—Cadaveric canine pelvic limbs (n=8 pairs).Methods—TPLO was stabilized with either conventional cortical screws or locking screws in a compressed osteotomy model. Titanium pins inserted into the tibial plateau and proximal metaphysis were used to track bone fragment location by computed tomography (CT) imaging. CT imaging was performed after osteotomy reduction, after plate stabilization, and after 30,000 cycles of axial compression testing. After 30,000 cycles, cyclic loading was continued with monotonically increasing peak‐load until failure.Results—The magnitude of rotation about the sawing axis was significantly greater for the conventional screw group because of plate application (P=.009). Translational movement of the tibial plateau fragment toward the plate was significantly greater for the conventional screw group (P=.006). There were no significant differences between groups in stiffness or number of cycles to failure.Conclusion—Maintenance of tibial plateau position was significantly superior for the locking screw group during plate application; however, screw type had no effect on fixation stability under cyclic loading.Clinical Relevance—These results suggest that conventional screws and careful contouring of the TPLO plate can provide comparable mechanical stability to fixation with locking screws in the tibial plateau under load‐sharing conditions, but potentially at the expense of osteotomy reduction.Keywords
This publication has 24 references indexed in Scilit:
- Biomechanics of Tibial Plateau Leveling of the Canine Cruciate‐Deficient Stifle Joint: A Theoretical ModelVeterinary Surgery, 2006
- The Effect of Tibial Plateau Leveling Osteotomy Position on Cranial Tibial Subluxation: An In Vitro StudyVeterinary Surgery, 2005
- A quasi-static three-dimensional, mathematical, three-body segment model of the canine kneeJournal of Biomechanics, 2004
- A Biomechanical Evaluation of Methods of Distal Humerus Fracture Fixation Using Locking Compression Plates Versus Conventional Reconstruction PlatesJournal of Orthopaedic Trauma, 2004
- Cranial cruciate ligament injury in the dog: pathophysiology, diagnosis and treatmentNew Zealand Veterinary Journal, 2003
- In Vitro Effects of Osteotomy Angle and Osteotomy Reduction on Tibial Angulation and Rotation During the Tibial Plateau‐Leveling Osteotomy ProcedureVeterinary Surgery, 2003
- Complications with and owner assessment of the outcome of tibial plateau leveling osteotomy for treatment of cranial cruciate ligament rupture in dogs: 193 cases (1997–2001)Journal of the American Veterinary Medical Association, 2003
- Surgical and postoperative complications associated with tibial plateau leveling osteotomy in dogs with cranial cruciate ligament rupture: 397 cases (1998–2001)Journal of the American Veterinary Medical Association, 2003
- Biomechanical Analysis of the Canine Hind Limb: Calculation of Forces During Three-legged StanceThe Veterinary Journal, 2002
- In vivo forces in the anterior cruciate ligament: Direct measurements during walking and trotting in a quadrupedJournal of Biomechanics, 1994