Tendon surface modification by chemically modified HA coating after flexor digitorum profundus tendon repair
Authors:
Open Access
- 19 November 2003
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 68B (1) , 15-20
Abstract
Carbodiimide derivatized HA (cd‐HA) is less soluble in water than normal HA, and therefore has an increased tissue residence time. The purpose of this study was to study the effect of cd‐HA gel on gliding and repair integrity during simulated repetitive motion of a repaired tendon in vitro. A total of 36 flexor digitorum profundus (FDP) tendons from six adult mongrel dogs were used and divided into three groups of control, simple HA, and cd‐HA. The gliding resistance between the FDP and the proximal pulley, FDS, and bone was measured before laceration and after modified Kessler technique repair at 1, 5, 10, 50, 100, 200, 300, 400, and 500 cycles. After gliding testing, failure load, tendon stiffness, and resistance to gap formation were measured. The results showed from the first cycle to the 10th cycle, there were no significant differences in gliding resistance between the three testing groups (p > 0.05). From the 50th cycle onwards, the friction was significantly lower in the cd‐HA gel group than in the control group (p < 0.05). Neither breaking strength, nor tendon stiffness, nor resistance to gap formation of the repairs were significantly different between the three groups (p > 0.05). © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 68B: 15–20, 2004Keywords
This publication has 36 references indexed in Scilit:
- Effects of increased in vivo excursion on digital range of motion and tendon strength following flexor tendon repairJournal of Orthopaedic Research, 1999
- Factors affecting results after flexor tendon repair in zone II: A multivariate prospective analysisThe Journal of Hand Surgery, 1993
- Measurement of range of motion of the finger after flexor tendon repair in zone II of the handThe Journal of Hand Surgery, 1993
- The Contents of Macromolecule Solutes in Flexor Tendon Sheath Fluid and Their Relation to Synovial FluidJournal of Hand Surgery (European Volume), 1992
- Flexor tendon forces: In vivo measurementsThe Journal of Hand Surgery, 1992
- Exogenous hyaluronate as an adjunct in the prevention of adhesions after flexor tendon surgery: A controlled clinical trialThe Journal of Hand Surgery, 1992
- Double loop locking suture: A technique of tendon repair for early active mobilization Part II: Clinical experienceThe Journal of Hand Surgery, 1990
- The modified kleinert splint in zone II flexor tendon injuriesJournal of Hand Surgery (European Volume), 1988
- Effect of Intra-articular Injection of Hyaluronic Acid on the Clinical Symptoms of Osteoarthritis and on Granulation Tissue FormationClinical Orthopaedics and Related Research, 1971
- Decreased Granulation Tissue Reaction After Installment of Hyaluronic AcidActa Orthopaedica, 1970