Some further observations from aircraft of frost point and temperature up to 50,000 ft
Authors:
- 1 April 1957
- journal article
- Published by Wiley in Quarterly Journal of the Royal Meteorological Society
- Vol. 83 (356) , 257-262
Abstract
During 1955, 46 measurements of frost point and temperature were made at varying altitudes up to about 50,000 ft using a Dobson‐Brewer pressurized frost‐point hygrometer and a flat‐plate thermometer mounted on the Canberra aircraft of the Meteorological Research Flight. The general character of these ascents in the lower stratosphere confirms the conclusions of earlier papers (Murgatroyd, Goldsmith and Hollings 1955). The mean frost point at 48,000 ft for the ascents made in 1954 and 1955 is ‐117°F and at 46,000 ft ‐115°F, with a standard deviation of about 3°F in each case.Keywords
This publication has 3 references indexed in Scilit:
- A method of increasing the range of the Dobson‐Brewer frost‐point hygrometer in jet aircraftQuarterly Journal of the Royal Meteorological Society, 1955
- Some recent measurements of humidity from aircraft up to heights of about 50,000 ft over southern EnglandQuarterly Journal of the Royal Meteorological Society, 1955
- Measurement of Absolute Humidity in Extremely Dry AirProceedings of the Physical Society (1926-1948), 1948