On charged particle equilibrium violation in external photon fields
- 27 February 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (3) , 1473-1480
Abstract
In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 35(11), 5179-5186 (2008)], requiring the beam to achieve charged particle equilibrium (CPE), in a time-averaged sense, in the reference medium. The relation obtained by Bouchard et al. was derived using Fano's theorem (1954) which states that if CPE is established in a given medium, the dose is independent of point-to-point density variations. A potential misconception on the achievability of the condition required by Fano (1954) might be responsible for false practical conclusions, both in the definition of PCSR fields as well as the theoretical model of quality correction factor. In this paper, the practical achievability of CPE in external beams is treated in detail. The fact that this condition is not achievable in single or composite deliveries is illustrated by an intuitive method and is also formally demonstrated. Fano's theorem is not applicable in external beam radiation dosimetry without (virtually) removing attenuation effects, and therefore, the relation conditionally defined by Bouchard et al. (2009) cannot be valid in practice. A definition of PCSR fields in the recent formalism for nonstandard beams proposed by Alfonso et al. (2008) should be modified, revising the criterion of CPE condition. The authors propose reconsidering the terminology used to describe standard and nonstandard beams. The authors argue that quality correction factors of intensity modulated radiation therapy PCSR fields (i.e., k(Q(pcsr),Q) (f(pcsr),f(ref) )) could be unity under ideal conditions, but it is concluded that further investigation is necessary to confirm that hypothesis.Keywords
This publication has 16 references indexed in Scilit:
- Calibration of helical tomotherapy machine using EPR/alanine dosimetryMedical Physics, 2011
- Effective point of measurement of thimble ion chambers in megavoltage photon beamsMedical Physics, 2009
- Ionization chamber gradient effects in nonstandard beam configurationsMedical Physics, 2009
- An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art IIMedical Physics, 2009
- The replacement correction factors for cylindrical chambers in high-energy photon beamsPhysics in Medicine & Biology, 2009
- On coupled Boltzmann transport equation related to radiation therapyJournal of Mathematical Analysis and Applications, 2007
- A new approach to the determination of air kerma using primary-standard cavity ionization chambersPhysics in Medicine & Biology, 2006
- Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTVRadiotherapy and Oncology, 2005
- Replacement correction factors for photon and electron dose measurementsMedical Physics, 1985
- Some Comments on Fano's TheoremRadiation Research, 1975