Abstract
A 4 month-old, 1.9 kg, female, Scottish Shorthair cat was brought to Kırıkkale University Veterinary Faculty Research and Practice Hospital with complaints of progressive dyspnea and exercise intolerance. Dorsal deformation in the caudal part of the sternum and displacement of the heart into the left hemithorax were determined in the clinical and radiographic examinations conducted. In the measurements made on the radiographic images taken before the operation, the frontosagittal index (FSI) and vertebral index (VI) values were measured as 3.5 and 5.1. Inoperative treatment, in order to correct the sternal malposition, an external splint made of PVC material is fixed to the thorax with suture material passed around the sternebrae. The patient was followed for 8 weeks after the operation. The external splint was removed five weeks after the operation, and the FSI and VI values were measured as 1.4 and 11.3 on the radiographs. The disappearance of the patient's dyspnea and exercise intolerance problems was observed in the postoperative period. In animals with bone development yet to be completed, it has been determined that external splint application gives successful results.

This publication has 15 references indexed in Scilit: