Dosimetric effect of modelling non-homogeneous LINAC couch using cone-beam computed tomography on quality assurance (QA) results
- 14 July 2022
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 22, 1-13
Abstract
Aim: To evaluate the dosimetric effect of modelling a non-homogeneous couch on patients’ quality assurance (QA) gamma pass rates for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques. Materials and Methods: A non-homogeneous treatment couch (TxT 550 TTM, CIVCO, USA) was imaged using the LINAC mounted cone-beam computer tomography (CBCT) system. Modelling this couch in different situations, including incomplete (homogeneous model), correct model and not defined situations in the treatment planning system (TPS), was performed based on the geometrical and material densities data extracted from the CBCT images. Calculated gamma pass rates between TPS dose calculations and the measurements in a phantom for different couch models were obtained and compared at two gamma criteria (2%-2 mm and 3%-3 mm). Results: Comparing TPS calculations for the correct modelled couch and the measurements showed high gamma pass rates for both the IMRT and VMAT techniques (96·5 ± 0·9%, 99·2 ± 0·5% for IMRT in 2%-2 mm and 3%-3 mm criteria; 97·5 ± 0·8%, 99·4 ± 0·5% for VMAT). The overall gamma pass rate of the IMRT plan QAs was reduced by about 2% and 3% on average for incomplete and no couch modelling, respectively. These reductions for VMAT techniques were 2·5% and 4·3%, respectively. Conclusions: Non-homogeneous couches have different parts with different attenuations, which can be correctly defined using LINAC CBCT. Modelling of treatment couch has a significant effect on patient QA results for VMAT and IMRT plans, especially in radiation fields/subfield transmitting from the couch. We suggest using LINAC CBCTs as an appropriate device for couch modelling in modulated radiotherapy techniques.Keywords
This publication has 15 references indexed in Scilit:
- Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatmentsJournal of Applied Clinical Medical Physics, 2016
- Evaluation of a new six degrees of freedom couch for radiation therapyMedical Physics, 2013
- A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT DoseRadiation Oncology, 2012
- IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119Medical Physics, 2009
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- Estimated limits of IMRT dose escalation using varied planning target volume marginsPhysics in Medicine & Biology, 2008
- Dose-guided radiation therapy with megavoltage cone-beam CTBritish Journal of Radiology, 2006
- IMRT: a review and previewPhysics in Medicine & Biology, 2006
- Radiation therapy dose escalation for prostate cancer: a rationale for IMRTWorld Journal of Urology, 2003
- The use of carbon fibres in radiotherapyRadiotherapy and Oncology, 1991