Abstract
Advancements in neuroendovascular devices have enabled greater access to distal, tortuous vasculature. However, this expanded capability also increases the risk of serious hemorrhagic complications during device navigation. The aim of the study is to quantify how microcatheter position and microguidewire stiffness affect tip contact force at a distal middle cerebral artery segment. A moderate tortuosity silicone model of the middle cerebral artery was used to evaluate three 0.014" Synchro SELECT microguidewires (Soft, Standard, Support) with a TrevoTrak 21 microcatheter positioned proximally in the M1 or distally in the M2 segment. Tip contact forces at the distal end of the M2 segment were recorded with a digital force gauge serving as a standardized surrogate for the distal vessel wall during motorized controlled wire advancement. From the force-distance curves, tip contact force slopes (mN/mm) and maximum tip contact forces (mN) were calculated and statistically compared across wire types and catheter positions. With distal microcatheter support, the average tip contact force slopes were 10.64 mN/mm (Soft), 10.85 mN/mm (Standard), and 15.28 mN/mm (Support) (p < 0.0001). With proximal support, the average slopes were significantly lower: 1.61 mN/mm (Soft), 3.15 mN/mm (Standard), and 3.87 mN/mm (Support) (p < 0.01). Distal microcatheter positioning consistently produced approximately 3 to 6-fold higher tip contact force slopes and higher maximum tip contact forces than proximal positioning. Microcatheter tip position and microguidewire stiffness were the primary determinants of tip contact force transmitted to distal vessel segments during neuroendovascular navigation in this model. Stiffer microguidewires exert significantly greater tip contact force, particularly when the microcatheter is positioned near the distal segment. Maintaining the microcatheter tip proximally attenuates these forces and offers a simple strategy to reduce mechanical loading of fragile distal branches during distal access procedures.Keywords
Funding Information
- Frederick Gardner Cottrell Foundation
- Tarsadia Foundation
- Jennifer Carroll Wilson Aneurysm Foundation
- Society of Vascular and Interventional Neurology (SVIN) Pilot Grant
This publication has 21 references indexed in Scilit:
- Medium- and Distal-Vessel Occlusion — The Limit of Thrombectomy?New England Journal of Medicine, 2025
- Endovascular Treatment for Stroke Due to Occlusion of Medium or Distal VesselsNew England Journal of Medicine, 2025
- Endovascular Treatment of Stroke Due to Medium-Vessel OcclusionNew England Journal of Medicine, 2025
- Can micro-guidewire advancement forces predict clot consistency and location to assist the first-line technique for mechanical thrombectomy?Journal of NeuroInterventional Surgery, 2024
- Incidence and outcome of perforations during medium vessel occlusion compared with large vessel occlusion thrombectomyJournal of NeuroInterventional Surgery, 2023
- Mechanical thrombectomy beyond the circle of Willis: efficacy and safety of different techniques for M2 occlusionsJournal of NeuroInterventional Surgery, 2021
- Stent retrievers with segmented design improve the efficacy of thrombectomy in tortuous vesselsJournal of NeuroInterventional Surgery, 2018
- Mechanical thrombectomy for acute ischemic stroke with occlusion of the M2 segment of the middle cerebral artery: a meta-analysisJournal of NeuroInterventional Surgery, 2017
- Manufacture of patient-specific vascular replicas for endovascular simulation using fast, low-cost methodScientific Reports, 2016
- Vessel perforation during stent retriever thrombectomy for acute ischemic stroke: technical details and clinical outcomesJournal of NeuroInterventional Surgery, 2016