Computer-assisted Total Knee Arthroplasty Using Patient-specific Templating
Authors:
- 1 March 2006
- journal article
- section ii
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 444, 184-192
Abstract
Current techniques used for total knee arthroplasty rely on conventional instrumentation that violates the intramedullary canals. Accuracy of the instrumentation is questionable, and assembly and disposal of the numerous pieces is time consuming. Navigation techniques are more accurate, but their broad application is limited by cost and complexity. We aimed to prove a new concept of computer-assisted preoperative planning to provide patient-specific templates that can replace conventional instruments. Computed tomography-based planning was used to design two virtual templates. Using rapid prototyping technology, virtual templates were transferred into physical templates (cutting blocks) with surfaces that matched the distal femur and proximal tibia. We performed 45 total knee arthroplasties on 16 cadaveric and 29 plastic knees, including a comparative trial against conventional instrumentations. All operations were performed using patient-specific templates with no conventional instrumentations, intramedullary perforation, tracking, or registration. The mean time for bone cutting was 9 minutes with a surgical assistant and 11 minutes without an assistant. Computer-assisted analyses of six random computed tomography scans showed mean errors for alignment and bone resection within 1.7° and 0.8 mm (maximum, 2.3° and 1.2 mm, respectively). Patient-specific templates are a practical alternative to conventional instrumentations, but additional clinical validation is required before clinical use.Keywords
This publication has 39 references indexed in Scilit:
- The effect of valgus/varus malalignment on load distribution in total knee replacementsJournal of Biomechanics, 2005
- Reoperations after 3200 Revision TKAsClinical Orthopaedics and Related Research, 2004
- Ergonomics in medicine and surgeryBMJ, 2004
- Instrumentation pitfalls: You just can't go on autopilot!The Journal of Arthroplasty, 2003
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002
- Untersuchungen zur Bildqualität, Hochkontrastauflösung und Dosis am Stamm- und Gliedmaßenskelett mit einem neuen dedizierten CT-System (ISO-C-3D)RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Anatomic variations should be considered in total knee arthroplastyJournal of Orthopaedic Science, 2000
- Effect of Rotation and Knee Flexion on Radiographic Alignment in Total Knee ArthroplastiesClinical Orthopaedics and Related Research, 1996
- Intramedullary versus extramedullary tibial alignment systems in total knee arthroplastyThe Journal of Arthroplasty, 1993
- Long-term Results after Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1987