Predictors of venous stenosis or occlusion following first transvenous cardiac device implantation: Prospective observational study
Open Access
- 11 December 2018
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 20 (5) , 495-500
Abstract
Introduction: Venous stenosis or occlusion related to an intracardiac device is a well-known complication of that procedure. There are numerous studies tried to determine predictors of venous stenosis or occlusion; however, most of them investigate the venous system prior to device upgrade, generator replacement, or transvenous lead extraction. Therefore, we aimed to assess the prevalence and determine the predictors of venous stenosis or occlusion following first transevnous cardiac device implantation. Methods: Observational, prospective study included 71 consecutive patients admitted for first transvenous cardiac device implantation. All patients were followed up for 6 months after operation. Results: Implanted device systems comprised cardioverter defibrillator (n = 26), single-chamber or dual-chamber pacemakers (n = 34), and biventricular pacemakers (n = 11); 88.5% of implantable cardioverter defibrillator leads were single-coils and 11.5% were dual-coils. The incidence of venous stenosis or occlusion within 6-month follow-up was 21.1%. Multivariate logistic regression showed that only diabetes or prediabetes (p = 0.033, odds ratio: 0.17, 95% confidence interval: 0.04–0.87), prolonged procedure time (p = 0.046, odds ratio: 4.54, 95% confidence interval: 1.01–20.12), and perioperative complications (p = 0.021, odds ratio: 7.04, 95% confidence interval: 1.35–36.85) were predictors of venous stenosis or occlusion. Conclusion: Prolonged implantation time (>60 min) and perioperative complications are associated with an increased risk of venous stenosis or occlusion, whereas diabetes and prediabetes significantly reduce the risk of venous stenosis or occlusion.Keywords
This publication has 23 references indexed in Scilit:
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Incidence and predictors of subclavian vein obstruction following biventricular device implantationJournal of Interventional Cardiac Electrophysiology, 2010
- Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgradeEP Europace, 2007
- Age, Size, and Lead Factors Alone Do Not Predict Venous Obstruction in Children and Young Adults with Transvenous Lead SystemsJournal of Cardiovascular Electrophysiology, 2006
- Venous Thrombosis and Stenosis After Implantation of Pacemakers and DefibrillatorsJournal of Interventional Cardiac Electrophysiology, 2005
- Incidence and Risk Factors of Early Venous Thrombosis Associated with Permanent Pacemaker LeadsJournal of Cardiovascular Electrophysiology, 2004
- Central venous catheter related thrombosis in haematology patients and prediction of risk by screening with Doppler‐ultrasoundBritish Journal of Haematology, 2003
- Prevalence of central venous occlusion in patients with chronic defibrillator leadsAmerican Heart Journal, 2001
- Postmortem Analysis of Encapsulation Around Long-Term Ventricular Endocardial Pacing LeadsMayo Clinic Proceedings, 1999
- Anatomical Findings in Patients Having Had a Chronically Indwelling Coronary Sinus Defibrillation LeadPacing and Clinical Electrophysiology, 1995