Structural modification of rhodamine-based sensors toward highly selective mercury detection in mixed organic/aqueous media
- 14 October 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- No. 47,p. 10457-10465
Abstract
In virtue of the sulfurphilic nature of Hg2+ , three new sensors RN1, RN2 and RST1 that combine a thiophene group and one or two rhodamine choromophores, or a thiospirolactam rhodamine chromophore, were designed and prepared for the selective detection of Hg2+ in aqueous media, respectively. These sensors all displayed good brightness and fluorescence enhancement following Hg2+ coordination with limits of detection for Hg2+ at the ppb level. Thus, they have the potential for distinguishing between safe and toxic levels of inorganic mercury in drinking water. RN1 exhibited chromogenic and fluorogenic selectivity over alkali, alkaline earth metals, divalent first-row transition metal ions as well as heavy metals, but the presence of Cu2+ had a small but significant influence on the absorption detection of Hg2+ . Compared to RN1, the introduction of sufficient sulfur atoms could increase the binding capability of RST1 towards Hg2+ relative to the sensor RN1, but decrease its Hg specific ability. The existence of some heavy and transition metal ions, such as Pb2+ , Ag+ , Cu2+ enhance the silent absorption spectra of RST1. Spectral evidence and X-ray structural investigations of the mercury complex revealed a possible 1:2 complexation behaviour between the Hg2+ ion and the sensor RN1 or RST1. Sensor RN2 which contains two rhodamine carboxhydrazone arms exhibited better selectivity, compared to those of RN1 and RST1. The addition of Cu2+ only caused a small interference for the absorption detection of Hg2+ under the same conditions, demonstrating the efficiency of the robust bis-chelating mode with regard to the selectivity for Hg2+ .Keywords
This publication has 55 references indexed in Scilit:
- Highly sensitive “turn-on” fluorescent sensor for Hg2+ in aqueous solution based on structure-switching DNAChemical Communications, 2008
- Reversible solid optical sensor based on acyclic-type receptor immobilized SBA-15 for the highly selective detection and separation of Hg(ii) ion in aqueous mediaChemical Communications, 2008
- A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ionsChemical Society Reviews, 2008
- Nanoscale Membrane Strips for Benign Sensing of HgII Ions: A Route to Commercial Waste TreatmentsAdvanced Functional Materials, 2008
- Diaza-18-crown-6 appended dual 7-hydroxyquinolines; mercury ion recognition in aqueous solutionChemical Communications, 2008
- Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting ProbeJournal of the American Chemical Society, 2007
- Design and Synthesis of Fluorescence “Turn-on” Chemosensors Based on Photoinduced Electron Transfer in Conjugated PolymersMacromolecules, 2005
- A Highly Selective and Sensitive Fluorescent Chemosensor for Hg2+ in Neutral Buffer Aqueous SolutionJournal of the American Chemical Society, 2004
- The Chemical Form of Mercury in FishScience, 2003
- Coupling Selectivity with Sensitivity in an Integrated Chemosensor Framework: Design of a Hg2+-Responsive Probe, Operating above 500 nmJournal of the American Chemical Society, 2003