Axillary vein puncture versus cephalic vein cutdown for cardiac implantable electronic device implantation: A meta‐analysis
Authors:
- 28 June 2023
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 46 (8) , 942-947
Abstract
Introduction: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile.Methods: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random‐effect model as risk ratio (RR) and relative 95% confidence interval (CI).Results: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09–1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: −8.25 min; 95% CI: −10.23 to −6.27; p < .0001; I2 = 0%) and venous access time (MD: −6.24 min; 95% CI: −7.01 to −5.47; p < .0001; I2 = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28–1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13−4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23–1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15–2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14–6.60; p = .96) and fluoroscopy time (MD: −0.24 min; 95% CI: −0.75 to 0.28; p = .36).Conclusion: Our meta‐analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.Keywords
This publication has 10 references indexed in Scilit:
- EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS)EP Europace, 2021
- Multi‐lead cephalic venous access and long‐term performance of high‐voltage leadsJournal of Cardiovascular Electrophysiology, 2021
- Axillary vein puncture guided by ultrasound vs cephalic vein dissection in pacemaker and defibrillator implant: A multicenter randomized clinical trialHeart Rhythm, 2020
- Subclavian and Axillary Vein Access Versus Cephalic Vein Cutdown for Cardiac Implantable Electronic Device ImplantationJACC: Clinical Electrophysiology, 2020
- Fluoroscopy‐guided axillary vein access vs cephalic vein access in pacemaker and defibrillator implantation: Randomized clinical trial of efficacy and safetyJournal of Cardiovascular Electrophysiology, 2019
- Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein accessEP Europace, 2017
- Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdownEP Europace, 2016
- A new trick to a routine procedure: taking the fear out of the axillary vein stick using the 35° caudal viewEP Europace, 2015
- Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association surveyEP Europace, 2013
- The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaborationBMJ, 2009