Digital autoradiography using room temperature CCD and CMOS imaging technology
Authors:
- Jorge CabelloJCJorge Cabello
- Alexis BaileyABAlexis Bailey
- Ian KitchenIKIan Kitchen
- Mark PrydderchMPMark Prydderch
- Andy ClarkACAndy Clark
- Renato TurchettaRTRenato Turchetta
- Kevin WellsKWKevin Wells
- 1 August 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (16) , 4993-5011
Abstract
CCD (charged coupled device) and CMOS imaging technologies can be applied to thin tissue autoradiography as potential imaging alternatives to using conventional film. In this work, we compare two particular devices: a CCD operating in slow scan mode and a CMOS-based active pixel sensor, operating at near video rates. Both imaging sensors have been operated at room temperature using direct irradiation with images produced from calibrated microscales and radiolabelled tissue samples. We also compare these digital image sensor technologies with the use of conventional film. We show comparative results obtained with (14)C calibrated microscales and (35)S radiolabelled tissue sections. We also present the first results of (3)H images produced under direct irradiation of a CCD sensor operating at room temperature. Compared to film, silicon-based imaging technologies exhibit enhanced sensitivity, dynamic range and linearity.Keywords
This publication has 35 references indexed in Scilit:
- Tritium autoradiography with thinned and back-side illuminated monolithic active pixel sensor deviceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Recent technologic developments on high-resolution beta imaging systems for quantitative autoradiography and double labeling applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Enhanced morphine withdrawal and µ‐opioid receptor G‐protein coupling in A2Aadenosine receptor knockout miceJournal of Neurochemistry, 2004
- Comparison of modern CCD and CMOS image sensor technologies and systems for low resolution imaging2003
- Lux transfer: CMOS versus CCD2002
- BETAview: a digital β-imaging system for dynamic studies of biological phenomenaNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- GaAs pixel arrays for β imaging in medicine and biologyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Autoradiography with silicon strip detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Optical imaging of the spatial distribution of beta-particles emerging from surfaces.Proceedings of the National Academy of Sciences, 1989
- A short atlas of beta-ray spectraPhysics in Medicine & Biology, 1983