Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca
- 28 May 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (12) , 4635-4649
Abstract
The coincidence time resolution (CTR) becomes a key parameter of 511keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. In this paper we present the results of CTR measurements on two different SiPM technologies from FBK coupled to LSO:Ce codoped 0.4%Ca crystals. We compare the measurements performed at two separate test setups, i.e. at CERN and at FBK, showing that the obtained results agree within a few percent. We achieve a best CTR value of 85 ± 4 ps FWHM for 2 × 2 × 3 mm 3 LSO:Ce codoped 0.4%Ca crystals, thus breaking the 100 ps barrier with scintillators similar to LSO:Ce or LYSO:Ce. We also demonstrate that a CTR of 140 ± 5 ps can be achieved for longer 2 × 2 × 20 mm 3 crystals, which can readily be implemented in the current generation PET systems to achieve the desired increase in the signal to noise ratio.Keywords
Funding Information
- Marie Curie Initial Training Network (289355)
- TICAL ERC (338933)
- SUBLIMA (241711)
This publication has 18 references indexed in Scilit:
- NUV Silicon Photomultipliers With High Detection Efficiency and Reduced Delayed Correlated-NoiseIEEE Transactions on Nuclear Science, 2015
- Characterization of Single-Photon Time Resolution: From Single SPAD to Silicon PhotomultiplierIEEE Transactions on Nuclear Science, 2014
- SiPM optical crosstalk amplification due to scintillator crystal: effects on timing performancePhysics in Medicine & Biology, 2014
- Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: an experimental and theoretical analysisJournal of Instrumentation, 2013
- Analog Circuit for Timing Measurements With Large Area SiPMs Coupled to LYSO CrystalsIEEE Transactions on Nuclear Science, 2013
- The DLED Algorithm for Timing Measurements on Large Area SiPMs Coupled to ScintillatorsIEEE Transactions on Nuclear Science, 2012
- Focus on time-of-flight PET: the benefits of improved time resolutionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Characterisation studies of silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- State of the art and challenges of time-of-flight PETPhysica Medica, 2009
- NINO: an ultra-fast and low-power front-end amplifier/discriminator ASIC designed for the multigap resistive plate chamberNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004