Softmax-based detection and localization of false data–injected measurements in a cyber-physical power system
- 12 January 2026
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (4) , 046201
Abstract
Cyber-physical power systems are among the most intricate industrial systems developed in current times. This complexity has also added many vulnerabilities to the system, with cyber attacks emerging as a severe threat in the recent past. Any attack on the cyber layer of the system can lead to disastrous consequences for control, monitoring, and operations of a physical system. Therefore, this paper presents a false data injection attack (FDIA) detection and localization technique in real time so that any data manipulations in the information layer by the adversary can be subverted before it affects the physical system. The proposed method exploits the inherent relationship among system data, governed by the physics of the system. The technique requires only a hundred past measurement data samples of the system during its normal operation, making it completely data-driven, model-agnostic, and extendable to any industrial cyber-physical system. Kullback–Leibler divergence between the softmax-based probability distribution of past samples and the real-time sample is used to analyze the sample for any FDIA. The detected sample with false data, if any, is further localized to identify the specific manipulated measurements using Chebyshev’s inequality. The developed technique is validated by exposing the IEEE-14 bus system and a modified IEEE-33 bus system with two different types of FDIA. The technique exhibits 100 percent accuracy in detection, whereas there are two false negatives in localization in the case of Ra-FDIA, due to the negligible manipulations created in those particular measurements during attack. A comparative analysis is also conducted to demonstrate that the proposed technique is 10 5 and 100 times faster than random matrix theory (RMT)–based and canonical variate analysis (10 449 386)–based method, respectively. The CO 2 emissions in the processing are also reduced by 10 6 times from RMT-based and around 10 3 times from CVA-based method for the 33-bus system, thus establishing the novelty of the proposed method.Keywords
This publication has 28 references indexed in Scilit:
- A novel strategy for fault location, isolation, and service restoration in active distribution networksMeasurement Science and Technology, 2025
- Method for identifying false data injection attacks in power grid based on improved CNN-LSTMElectrical Engineering, 2025
- HGCNN-LSTM: A Data-driven Approach for Cyberattack Detection in Cyber-Physical SystemsSN Computer Science, 2025
- Joint detection and localization of False Data Injection Attacks in smart grids: An enhanced state estimation approachComputers and Electrical Engineering, 2024
- Applications of machine learning in real-time control systems: a reviewMeasurement Science and Technology, 2024
- Anomaly detection model for large-scale industrial systems using transfer entropy and graph attention networkMeasurement Science and Technology, 2024
- False Data Injection Attack Detection for Smart Grid Based on Square Root Unscented Kalman Filtering Estimate with Long Short Term Memory CorrectionJournal of Electrical Engineering & Technology, 2024
- Detection, differentiation and localization of replay attack and false data injection attack based on random matrixScientific Reports, 2024
- Artificial intelligence for carbon emissions using system of systems theoryEcological Informatics, 2023
- A data-driven technique for harmonics monitoring in emerging power grids using noise-aware dynamic mode decompositionMeasurement Science and Technology, 2019