Abstract
Keypoints: Tracheo‐oesophageal fistula and voice prosthesis have revolutionised voice rehabilitation, but are not without their complications. The most significant problem is widening of the tracheo‐oesophageal fistula relative to the voice prosthesis and subsequent leaking. Three‐layer surgical closure is a means of permanently closing a problematic fistula. Use of an interposition in situ muscle graft as a second layer provides an adequate, well vascularised barrier to prevent fistula reformation. Our technique provides a safe, effective method of closing a problematic tracheo‐oesophageal fistula. We report a five case series in which 100% of patients acquired satisfactory closure of their fistulae and resolution of their symptoms.

This publication has 8 references indexed in Scilit: