Postoperative displacement of hydroxyapatite spacers implanted during double-door laminoplasty
- 1 June 2009
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 10 (6) , 551-556
Abstract
Object: Double-door laminoplasty using hydroxyapatite (HA) spacers has been widely performed for compressive cervical myelopathy and has provided good neurological outcome. Although HA spacers are used for preventing reclosure of the opened laminae, they are often displaced or dislocated from their original position. The authors investigated the incidence and patterns of postoperative HA spacer displacement to determine the reasons for this unfavorable event. Methods: Eighty-six patients with compressive myelopathy underwent double-door laminoplasty in which a total of 278 HA spacers were used. The displacement of HA spacers and opened laminae were assessed using postoperative lateral radiographs and CT scans. Results: Postoperative dorsal migration > 2 mm was found in 116 (42%) of 278 implanted HA spacers. In addition, 33 (38%) of 86 HA spacers rotated > 10° and 29 (34%) of the 86 opened laminae tilted > 10°. Moreover, deformation of the newly formed spinal canal was observed in 51 (59%) of 86 cases, and bone fusion between the HA spacer and spinous process was achieved in only 15 (8.7%) of 172 cases. Neurological worsening and neck pain, however, were not associated with displacement of HA spacers or deformation of the spinal canal. Conclusions: In double-door laminoplasty, postoperative displacement of the HA spacer with deformation of the enlarged spinal canal occurred frequently. Hydroxyapatite spacers tend to become displaced after surgery. Placing the HA spacer at the base of the spinous process close to the dura mater may prevent postoperative displacement.Keywords
This publication has 13 references indexed in Scilit:
- En bloc laminoplasty without dissection of paraspinal musclesJournal of Neurosurgery: Spine, 2005
- Bilateral open-door cervical expansive laminoplasty with hydroxyapatite spacers and titanium screwsJournal of Neurosurgery: Spine, 2002
- Long-Term Results of Double-Door Laminoplasty for Cervical Stenotic MyelopathySpine, 2001
- Contact of hydroxyapatite spacers with split spinous processes in double-door laminoplasty for cervical myelopathyJournal of Orthopaedic Science, 1999
- Expansive cervical laminoplasties – observations on comparative changes in spinous process lengths following longitudinal laminal divisions using autogenous bone or hydroxyapatite spacersSpinal Cord, 1996
- Spinous Process-Splitting Laminoplasty Using Hydroxyapatite Spinous Process SpacerSpine, 1992
- Bilateral Open Laminoplasty Using Ceramic Laminas for Cervical MyelopathySpine, 1991
- Cervical Laminoplasty (Hattoriʼs Method)Spine, 1988
- Technical Improvements and Results of Laminoplasty for Compressive Myelopathy in the Cervical SpineSpine, 1985
- Expansive Open-Door Laminoplasty for Cervical Spinal Stenotic MyelopathySpine, 1983