Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope
- 15 May 2018
- journal article
- research article
- Published by Galenos Yayinevi in Turkish Journal of Anesthesia and Reanimation
- Vol. 46 (1) , 44-50
Abstract
Endotracheal intubation should be performed with care when cervical spine (C-spine) injury is suspected. The aim of this study was to evaluate the movement of the C-spine using fluoroscopy during intubation with Laryngeal Mask Airway (LMA) CTrach, C-MAC videolaryngoscope and Macintosh laryngoscope. This was a single-centre, prospective, observational, controlled trial. In total, 22 surgical patients aged 18-65 years planned to undergo operation under general anaesthesia, were enrolled. X-ray images of the C-spine were obtained using fluoroscopy with the patients' head in a neutral position. All patients underwent laryngoscopy using a Macintosh blade, LMA CTrach and C-MAC videolaryngoscope, and fluoroscopic images of the C-spine were obtained. All the patients were intubated at the last laryngoscopy simulation (using the C-MAC). The atlanto-occipital distance (AOD) and angles between C0C1, C0C2, C0C3, C0C4, C1C2 and C2C3 lines were measured and compared between each device. The mean AOD was measured as 20.4 mm in a neutral position, which decreased to 13.1, 17.2 and 12.3 mm after the insertion of the Macintosh laryngoscope, LMA CTrach and C-MAC videolaryngoscope, respectively. The differences were significant (p<0.001). Moreover, significant difference was noted in C0C2, C0C3 and C1C2 angles with the insertion of the three devices (p<0.001). The LMA CTrach resulted in significantly lesser C-spine movements in C0C2, C0C3 and C0C4 angles compared to the Macintosh laryngoscope and C-MAC videolaryngoscope (p<0.001). The LMA CTrach resulted in lesser C-spine movements compared to Macintosh laryngoscope and C-MAC videolaryngoscope. In case of the C-spine injury, LMA CTrach may be preferred and may cause fewer traumas during endotracheal intubation.Keywords
This publication has 29 references indexed in Scilit:
- Upper cervical spine movement during intubation with different airway devicesThe American Journal of Emergency Medicine, 2013
- LMA C Trach aided endotracheal intubation in simulated cases of cervical spine injury: A series of 30 casesSaudi Journal of Anaesthesia, 2013
- Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope®British Journal of Anaesthesia, 2009
- Success of Tracheal Intubation with Intubating Laryngeal Mask AirwaysAnesthesiology, 2008
- The LMA CTrach™, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patientsBritish Journal of Anaesthesia, 2006
- Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscopeAnaesthesia, 2005
- The Reliability of the Bellhouse Test for Evaluating Extension Capacity of the Occipitoatlantoaxial ComplexAnesthesia & Analgesia, 2002
- Critical Care of Spinal Cord InjurySpine, 2001
- Segmental Cervical Spine Movement with the Intubating Laryngeal Mask During Manual In-Line Stabilization in Patients with Cervical Pathology Undergoing Cervical Spine SurgeryAnesthesia & Analgesia, 2000
- Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard™ laryngoscopes, the Bonfils fibrescope and the Intubating Laryngeal Mask Airway1999