Capture management efficacy in children and young adults with endocardial and unipolar epicardial systems
Open Access
- 1 May 2004
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 6 (3) , 248-255
Abstract
This prospective study characterized performance of the Kappa 700 Ventricular Capture Management™ (VCM) system for monitoring ventricular pacing threshold and adapting outputs in both endocardial and unipolar epicardial pacing systems in children and young adults. VCM bears cautionary labelling against use with epicardial leads since they have not been demonstrated appropriate for use with VCM. VCM was programmed in “Monitor Only” mode. Ventricular pacemaker thresholds were measured daily using VCM for a minimum of 2 months. Potential device longevities at nominal outputs (3.5 V, 1.0 ms) and at VCM-recommended outputs were compared. Thirty patients {median age 14.4 years (1–27 years); 15 epicardial/15 endocardial} completed the study. During the daily measurements, consistent undersensed evoked response occurred in 2 patients (Medtronic epicardial leads 4965). For the other 28 patients, programming VCM in “Adaptive” mode from implant would provide an additional 6.8 months (0–19 months) of battery life. Although not an IDE (Investigation Device Exemption) study, this study showed acceptable VCM performance in “Monitor Only” mode in 13/15 patients with unipolar epicardial leads. A 2-month “Monitor Only” observation period helps screen patients who might not benefit from VCM. VCM may provide substantial energy savings and extended battery life for children and young adults.Keywords
This publication has 9 references indexed in Scilit:
- A Prospective Multicenter Study on the Safety of a Pacemaker with Automatic Energy Control: Influence of the Electrical Factor on Chronic Stimulation Threshold.Pacing and Clinical Electrophysiology, 2000
- Automatic Threshold Tracking Activation Without the Intraoperative Evaluation of the Evoked Response AmplitudePacing and Clinical Electrophysiology, 2000
- Low-energy epicardial pacing in children: the benefit of autocaptureThe Annals of Thoracic Surgery, 1999
- Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptationThe Annals of Thoracic Surgery, 1999
- Steroid‐Eluting Epicardial Pacing Electrodes: Six Year Experience of Pacing Thresholds in a Growing Pediatric PopulationPacing and Clinical Electrophysiology, 1997
- Epicardial pacing using a pacemaker with Autocapture™ algorithm in an infantInternational Journal of Cardiology, 1997
- The cost-effectiveness of dual-chamber pacingEuropean Heart Journal, 1996
- Steroid-eluting epicardial pacing leads in pediatric patients: Encouraging early resultsJACC, 1992
- Improved Chronic Epicardial Pacing in Children: Steroid Contribution to Porous Platinized ElectrodesPacing and Clinical Electrophysiology, 1992