Efficiency ultrasound full-matrix imaging of heterogeneous-anisotropic CFRP laminate multilayer composite structure internal defects

Authors:

Abstract
Carbon Fiber Reinforced Polymer (CFRP) components are widely used in engineering for their high strength, high modulus and lightweight properties to enhance product performance. Ultrasonic full-matrix imaging is an effective method to identify the defects in various components, but the Quasi-Pressure (QP) velocity anisotropy of CFRP severely impairs measurement accuracy and efficiency. The total focusing method (TFM) can deal with the velocity anisotropy through ray-tracing method, but the high computational complexity makes the method very time-consuming. To address this issue, an anisotropic phase shift migration is proposed in this study. The anisotropic vertical wavenumber is calibrated by the QP velocity. Then, the wavefield extrapolation in anisotropic medium is implemented by phase shift migration in the frequency-wavenumber domain. The proposed method is validated by simulations and experiments on diverse CFRP laminates, wherein the imaging quality of the proposed method is comparable with the ray-based homogeneous model TFM while the time cost is several orders of magnitude smaller than the latter (on the order of 10-6). Therefore, it shows great potential in defect detection for industrial CFRP products.

This publication has 27 references indexed in Scilit: