Site-specific Quantification of Bone Quality using Highly Nonlinear Solitary Waves
Authors:
Preprint
Abstract
Osteoporosis is a well recognized problem affecting millions of individuals worldwide. Consequently, the need to effectively, efficiently, and affordably diagnose and identify those at risk is essential; moreover, site-specific assessment of bone quality is necessary, not only in the process of risk assessment, but may also be desirable for other applications. The present study evaluated a new one-dimensional granular crystal sensor, composed of a tightly packed chain of beads under Hertzian contact interaction, representing the most suitable fundamental component for solitary wave generation and propagation. First, the sensitivity of the novel sensor was tested using densities of rigid polyurethane foam, representing clinical bone quality ranging from healthy, to severely osteoporotic. Once the relationship between the signal response and known densities was established, the sensor was used to measure several sites located in the proximal femur of ten human cadaveric specimens. The accuracy of the model was then further investigated, using measurements of bone quality from the same cadaveric specimens, independently, using DEXA. The results indicate not only that the novel technique is capable of detecting differences in bone quality, but that the ability to measure site-specific properties without exposure to radiation, has the potential to be further developed for clinical applications.Keywords
All Related Versions
This publication has 37 references indexed in Scilit:
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030Clinical Orthopaedics and Related Research, 2009
- Multiplanar variations in the structural characteristics of cancellous boneBone, 1994
- Geometric variables from DXA of the radius predict forearm fracture load in vitroCalcified Tissue International, 1993
- Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurementsJournal of Biomechanics, 1993
- Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomographyJournal of Orthopaedic Research, 1991
- Estimation of mechanical properties of cortical bone by computed tomographyJournal of Orthopaedic Research, 1991
- Young's modulus, bending strength, and tissue physical properties of human compact boneJournal of Orthopaedic Research, 1990
- Biomechanical properties of the proximal femur determined in vitro by single-energy quantitative computed tomographyJournal of Bone and Mineral Research, 1989
- The mechanical properties of trabecular bone: Dependence on anatomic location and functionJournal of Biomechanics, 1987
- Mechanical properties of human cancellous bone in the femoral headMedical & Biological Engineering & Computing, 1974