Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes
Open Access
- 31 October 2013
- journal article
- research article
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2013, 1-10
Abstract
The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.Keywords
Funding Information
- King Abdulaziz City for Science and Technology (10-ENE1371-04)
This publication has 8 references indexed in Scilit:
- An experimental and analytical study of the effect of axial power profile on CHFNuclear Engineering and Design, 2006
- An independent assessment of Groeneveld et al.'s 1995 CHF look-up tableNuclear Engineering and Design, 1997
- The 1995 look-up table for critical heat flux in tubesNuclear Engineering and Design, 1996
- SIMPLE METHOD FOR SMOOTHING MULTIDIMENSIONAL EXPERIMENTAL DATA WITH APPLICATION TO THE CHF AND POSTDRYOUT LOOK-UP TABLESNumerical Heat Transfer, Part B: Fundamentals, 1994
- The physical closure laws in the CATHARE codeNuclear Engineering and Design, 1990
- 1986 AECL-UO Critical Heat Flux Lookup TableHeat Transfer Engineering, 1986
- A model for predicting flow regime transitions in horizontal and near horizontal gas‐liquid flowAIChE Journal, 1976
- Heat Transfer at High Rates to Water with Surface BoilingIndustrial & Engineering Chemistry, 1949