Bedside end-tidal CO2tension as a screening tool to exclude pulmonary embolism
Authors:
- A. R. HemnesAHA. R. Hemnes
- A. L. NewmanANA. L. Newman
- B. RosenbaumBRB. Rosenbaum
- T. W. BarrettTBT. W. Barrett
- C. ZhouCZC. Zhou
- T. W. RiceTRT. W. Rice
- J. H. NewmanJNJ. H. Newman
Open Access
- 28 August 2009
- journal article
- research article
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 35 (4) , 735-741
Abstract
End tidal carbon dioxide tension (PET,CO2) is a surrogate for dead space ventilation which may be useful in the evaluation of pulmonary embolism (PE). We aimed to define the optimalPET,CO2level to exclude PE in patients evaluated for possible thromboembolism.298 patients were enrolled over 6 months at a single academic centre.PET,CO2was measured within 24 h of contrast-enhanced helical computed tomography, lower extremity duplex or ventilation/perfusion scan. Performance characteristics were measured by comparing test results with clinical diagnosis of PE.PE was diagnosed in 39 (13%) patients. MeanPET,CO2in healthy volunteers did not differ fromPET,CO2in patients without PE (36.3±2.8versus35.5±6.8 mmHg).PET,CO2in patients with PE was 30.5±5.5 mmHg (pversuspatients without PE). APET,CO2of ≥36 mmHg had optimal sensitivity and specificity (87.2 and 53.0%, respectively) with a negative predictive value of 96.6% (95% CI 92.3–98.5). This increased to 97.6% (95% CI 93.2–99.) when combined with Wells score PET,CO2of ≥36 mmHg may reliably exclude PE. Accuracy is augmented by combination with Wells score.PET,CO2should be prospectively compared to D-dimer in accuracy and simplicity to exclude PE.Keywords
This publication has 25 references indexed in Scilit:
- Simple and Accurate Prediction of the Clinical Probability of Pulmonary EmbolismAmerican Journal of Respiratory and Critical Care Medicine, 2008
- Pulmonary Embolism Incidence Is Increasing with Use of Spiral Computed TomographyThe American Journal of Medicine, 2008
- Acute Pulmonary EmbolismNew England Journal of Medicine, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- American College of Radiology White Paper on Radiation Dose in MedicineJournal of the American College of Radiology, 2007
- Diagnostic accuracy of D‐dimer test for exclusion of venous thromboembolism: a systematic reviewJournal of Thrombosis and Haemostasis, 2007
- Multidetector Computed Tomography for Acute Pulmonary EmbolismNew England Journal of Medicine, 2006
- Multidetector-Row Computed Tomography in Suspected Pulmonary EmbolismNew England Journal of Medicine, 2005
- Excluding Pulmonary Embolism at the Bedside without Diagnostic Imaging: Management of Patients with Suspected Pulmonary Embolism Presenting to the Emergency Department by Using a Simple Clinical Model and d-dimerAnnals of Internal Medicine, 2001
- Contrast Material-Induced Renal Failure in Patients with Diabetes Mellitus, Renal Insufficiency, or BothNew England Journal of Medicine, 1989