Abstract
Scanning electrochemical microscopy (SECM), a non-invasive variant of scanning probe microscopy, can be used to measure oxygen uptake or insulin secretion of isolated murine pancreatic islets in the presence of low and high physiological glucose concentrations levels. SECM imaging of islet topography and islet oxygen uptake is accomplished by the use of a redox mediator that cannot penetrate into the cell membranes of the islet coupled to direct reduction of oxygen at the SECM tip. An insulin sensing ultramicroelectrode (UME), adapted from a macro-scale insulin sensor incorporating a multiwalled carbon nanotube/dihydropyran film developed in our lab previously, was used for the direct electrochemical detection of insulin levels within extracellular media in real-time. We were able to stimulate and record increased insulin production in a single pancreatic islet by raising the concentration of extracellular glucose to the physiological ‘high level.’ These experiments generated probe scan curves (PSCs) for insulin production in the extracellular media surrounding single pancreatic islets extracted from male mice. This research is a part of an ongoing attempt to increase the scope of application for Bio-SECM, both through the adaptation of specialized biosensors and application of existing techniques for biological analysis of single cells and micro-organs.Keywords
This publication has 69 references indexed in Scilit:
- Electrochemical Sensors and BiosensorsAnalytical Chemistry, 2011
- Scanning Electrochemical Microscopy in NeuroscienceAnnual Review of Analytical Chemistry, 2010
- Glucose and Lactate Biosensors for Scanning Electrochemical Microscopy Imaging of Single Live CellsAnalytical Chemistry, 2008
- A multiwalled carbon nanotube/dihydropyran composite film electrode for insulin detection in a microphysiometer chamberAnalytica Chimica Acta, 2008
- Rapid intraoperative insulin assay: a novel method to differentiate insulinoma from nesidioblastosis in the pediatric patientAnnals of Surgical Innovation and Research, 2007
- Fabrication of Boron-Doped Diamond Ultramicroelectrodes for Use in Scanning Electrochemical Microscopy ExperimentsAnalytical Chemistry, 2007
- Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodesAnalytica Chimica Acta, 2007
- Electrochemical detection of trace insulin at carbon-nanotube-modified electrodesAnalytica Chimica Acta, 2004
- Modification of the Cytosensor™ microphysiometer to simultaneously measure extracellular acidification and oxygen consumption ratesAnalytica Chimica Acta, 2003
- Detection of Multiple Patterns of Oscillatory Oxygen Consumption in Single Mouse Islets of LangerhansBiochemical and Biophysical Research Communications, 1999