Numerical comparison of local transceiver arrays of fractionated dipoles and microstrip antennas for body imaging at 7 T
Open Access
- 17 March 2022
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (8) , e4722
Abstract
Longitudinally orientated dipoles and microstrip antennas have both demonstrated superior results as RF transmit elements for body imaging at 7 T MRI, and are as of today the most commonly used transmit elements. In this study, the performances of the two antenna concepts were compared for use in local RF antenna arrays by numerical simulations. Antenna elements investigated are the fractionated dipole and the microstrip line with meander structures. Phantom simulations with a single antenna element were performed and evaluated with regard to specific absorption rate (SAR) efficiency in the center of the subject. Simulations of array configurations with 8 and 16 elements were performed with anatomical body models. Both antenna elements were combined with a loop coil to compare hybrid configurations. Singular value decomposition of the B1+ fields, RF shimming, and calculation of the voxel‐wise power and SAR efficiencies were performed in regions of interest with varying sizes to evaluate the transmit performance. The signal‐to‐noise ratio (SNR) was evaluated to estimate the receive performance. Simulated data show similar transmit profiles for the two antenna types in the center of the phantom (penetration depth > 20 mm). For body imaging, no considerable differences were determined for the different antenna configurations with regard to the transmit performance. Results show the advantage of 16 transmit channels compared with today's commonly used 8‐channel systems (minimum RF shimming excitation error of 4.7% (4.3%) versus 2.7% (2.8%) for the 8‐channel and 16‐channel configurations with the microstrip antennas in a (5 cm)3 cube in the center of a male (female) body model). Highest SNR is achieved for the 16‐channel configuration with fractionated dipoles. The combination of either fractionated dipoles or microstrip antennas with loop coils is more favorable with regard to the transmit performance compared with only increasing the number of elements.Keywords
This publication has 35 references indexed in Scilit:
- Bloch-based MRI system simulator considering realistic electromagnetic fields for calculation of signal, noise, and specific absorption rateMagnetic Resonance in Medicine, 2013
- Design of a radiative surface coil array element at 7 T: The single‐side adapted dipole antennaMagnetic Resonance in Medicine, 2011
- Local specific absorption rate control for parallel transmission by virtual observation pointsMagnetic Resonance in Medicine, 2011
- Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitationsMagnetic Resonance in Medicine, 2009
- Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channelsMagnetic Resonance in Medicine, 2008
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- Erratum to Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med. 2005;54:1439–1447.Magnetic Resonance in Medicine, 2007
- Spatial domain method for the design of RF pulses in multicoil parallel excitationMagnetic Resonance in Medicine, 2006
- Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequenciesMagnetic Resonance in Medicine, 2005
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005