Effect of repetition time on metabolite quantification in the human brain in 1H MR spectroscopy at 3 tesla
- 30 July 2016
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 45 (3) , 710-721
Abstract
Purpose: To examine the effects of repetition time (TR) on metabolite concentration measurements in the human brain in 1H magnetic resonance spectroscopy at 3 Tesla (T).Materials and Methods: Spectra were acquired from the posterior cingulate of five healthy adults at repetition times of 1.5 s, 3.0 s, 4.0 s, 6.0 s, and 8.0 s on a 3T MRI system. Relaxation data were also acquired for the water signal in the voxel of interest to separate tissue water and cerebrospinal fluid signal contributions. All data were quantified relative to total creatine and relative to the tissue water signal.Results: On average, the variance for absolute metabolite concentrations was smaller than that of ratio concentrations (P = 0.003). Metabolite ratio concentrations calculated from a short TR of 1.5 s significantly differed (P < 0.05) from their “true” ratios, i.e., ratios corrected for T1‐weighting. In comparison, absolute metabolite concentrations exhibited significant differences (P < 0.05) up to a 4‐s TR.Conclusion: To minimize potential TR‐dependent concentration differences at 3T, a minimum TR of 2.5 s is suggested for ratio concentration measurements, and a 5‐s TR for absolute concentrations. When possible, preference should be to perform absolute concentration measurements.Level of Evidence: 2J. Magn. Reson. Imaging 2017;45:710–721.Keywords
This publication has 30 references indexed in Scilit:
- Noninvasive quantification of ascorbate and glutathione concentration in the elderly human brainNMR in Biomedicine, 2011
- In vivo 1H NMR spectroscopy of the human brain at 9.4T: Initial resultsJournal of Magnetic Resonance, 2010
- In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7TMagnetic Resonance in Medicine, 2009
- Comparison of T1 and T2 metabolite relaxation times in glioma and normal brain at 3TJournal of Magnetic Resonance Imaging, 2008
- GAVA: Spectral simulation for in vivo MRS applicationsJournal of Magnetic Resonance, 2007
- On restoring motion‐induced signal loss in single‐voxel magnetic resonance spectraMagnetic Resonance in Medicine, 2006
- Proton NMR chemical shifts and coupling constants for brain metabolitesNMR in Biomedicine, 2000
- In vivo proton magnetic resonance spectroscopy of the normal aging human brainLife Sciences, 1996
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance ExperimentsPhysical Review B, 1954