Real-Time In Situ Navigation System With Indocyanine Green Fluorescence for Sentinel Lymph Node Biopsy in Patients With Breast Cancer
Authors:
Open Access
- 5 May 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Abstract
Background: The naked-eye invisibility of indocyanine green fluorescence limits the application of near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node biopsy (SLNB) in patients with breast cancer undergoing surgery. This study aims to evaluate the effectiveness and safety of a novel NIR system in visualizing indocyanine green fluorescence images in the surgical field and the application value of combined methylene blue (MB) and the novel NIR system in SLNB. Methods: Sixty patients with clinical node-negative breast cancer received indocyanine green (ICG) and MB as tracers. Two NIR system instruments, namely, lymphatic fluorescence imaging system (LFIS) designed by the University of Science and Technology of China and vascular imager by Langfang Mingde Medical Biotechnology Co., Ltd. (Langfang vascular imager), were used as navigation assistance to locate sentinel lymph nodes (SLNs). Excising the lymph nodes developed by both MB and ICG by two NIR systems or palpably suspicious as SLNs and undergoing rapid pathological examination. Results: Both instruments exhibited 95% (57/60) success for real-time lymphatic fluorescent images. A total of 186 SLNs were identified, of which two were pathologically confirmed as lacking any lymph node tissue. SLN identification rate was 100% (184/184) for MB plus LFIS and 86.96% (160/184) for MB alone. The median number of SLNs identified by LFIS combined with MB was 3 (range of 1–8), which was significantly higher than that by MB alone at 2 (range 1–7) (PConclusion: LFIS effectively detects SLNs in breast cancer, projects the fluorescence signals during surgery, and provides a continuous surgical navigation system without the need for a remote monitor. The ICG method navigated by combined LFIS and MB may be a promising alternative tracer for radioisotope in SLN mapping. Clinical Trial Registration: This clinical trial was registered with the China Clinical Trial Center, registration number ChiCTR2000039542.Keywords
All Related Versions
This publication has 23 references indexed in Scilit:
- Diagnostic Performance of Indocyanine Green-Guided Sentinel Lymph Node Biopsy in Breast Cancer: A Meta-AnalysisPLOS ONE, 2016
- Evaluation of the Clinical Utility of the ICG Fluorescence Method Compared with the Radioisotope Method for Sentinel Lymph Node Biopsy in Breast CancerAnnals of Surgical Oncology, 2015
- Novel techniques for sentinel lymph node biopsy in breast cancer: a systematic reviewThe Lancet Oncology, 2014
- Randomized Comparison of Near-infrared Fluorescence Imaging Using Indocyanine Green and 99m Technetium With or Without Patent Blue for the Sentinel Lymph Node Procedure in Breast Cancer PatientsAnnals of Surgical Oncology, 2012
- How Many Sentinel Lymph Nodes Are Enough for Accurate Axillary Staging in T1-2 Breast Cancer?Journal of Breast Cancer, 2011
- Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trialThe Lancet Oncology, 2010
- Evaluation of sentinel node biopsy by combined fluorescent and dye method and lymph flow for breast cancerThe Breast, 2010
- Technical outcomes of sentinel-lymph-node resection and conventional axillary-lymph-node dissection in patients with clinically node-negative breast cancer: results from the NSABP B-32 randomised phase III trialThe Lancet Oncology, 2007
- Management of the axilla in women with breast cancerThe Breast, 2007
- Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancerBreast Cancer, 2005