Development and application of a micro-capillary rheometer for in-vitro evaluation of parenteral injectability
Authors:
- 1 June 2004
- journal article
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 56 (6) , 709-716
Abstract
A micro-capillary rheometer was developed to determine the rheology and injectability of parenteral formulations. The rheometer consisted of a micro-capillary and a glass syringe attached to an Instron that drove the syringe plunger at predetermined speeds and measured resulting forces on the plunger. The cross-head speed and the measured force were used to calculate the shear rate and the shear stress respectively, according to the Hagen-Poiseuille equation. The resulting rheograms of several Newtonian standards showed excellent linearity over a broad range of about 10 times 103 to 160 times 103 s−1 and produced accurate and reproducible viscosity determinations over the viscosity range of about 10 times 10−3 to 100 times 10−3 Pa.s. The developed methodology focussed primarily on the minimization of errors associated with the determination of the wall frictional force using both direct measurement and linear regression to determine this parameter from the data. The effect of micro-capillary diameter, syringe cross-sectional area and micro-capillary length was explored in an effort to increase the measured force so that wall frictional force errors could be minimized. The micro-capillary rheometer gave reproducible and accurate rheograms over a range of shear rates consistent with the shear rate range used in clinical practice, and showed that Newtonian and non-Newtonian rheological behaviours could be evaluated quantitatively.Keywords
This publication has 12 references indexed in Scilit:
- Rheological behavior of short sisal fiber-reinforced polystyrene compositesComposites Part A: Applied Science and Manufacturing, 2000
- Observations of shear-induced particle migration for oscillatory flow of a suspension within a tubePhysics of Fluids, 1999
- Piston-driven flow of highly concentrated suspensionsJournal of Rheology, 1999
- Capillary Flow Behaviour of Microcrystalline Wax and Silicon Carbide SuspensionJournal of Materials Science, 1998
- Pain of Local Anesthetics: Rate of Administration and BufferingAnnals of Emergency Medicine, 1998
- Flow of RX-08-FK high-energy paste in a capillary rheometerJournal of Rheology, 1997
- Rheological Behavior of Injection‐Moldable Silicon Powder–Silicon Carbide Whisker FormulationsJournal of the American Ceramic Society, 1993
- Separation of Elastic and Shear Thinning Effects in the Capillary RheometerTransactions of the Society of Rheology, 1977
- Suspended Particles in Fluid Flow Through TubesAnnual Review of Fluid Mechanics, 1971
- End Corrections in the Capillary Flow of PolyethyleneJournal of Applied Physics, 1957