New numerical evaluation of parallelepiped NaI(Tl) detector geometrical and total efficiencies using extended sources
Authors:
- 19 September 2017
- journal article
- Published by EDP Sciences in Radioprotection
- Vol. 52 (4) , 265-271
Abstract
Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. The design of 4πNaI(Tl) parallelepiped γ-ray scintillation detector with central square left void is considered an instructive case in radiation measurements, where it can be easily used in several critical applications including medical therapy, radiation protection, environmental exposure monitoring and neutron interaction. It is also extremely important to measure the activities of low radioactivity samples. Therefore, the understanding of the full scope of the multidimensional calibration and measurement process must be done with high accuracy. The present work is essentially concerned in introducing a new numerical evaluation to calculate the geometrical and total efficiency of a 4πNaI(Tl) parallelepiped scintillator detector using isotropic radiating γ-ray point source. Also the average path lengths traveled by the photon inside the detector active medium have been calculated in order to study the characteristics of the source-to-detector configurations. This method depends mainly on the calculation of the solid angle subtended to the radioactive point source situated at various positions inside the detector and the photon path lengths through the detector active medium. In addition, the attenuation of the stainless steel absorber between the source and the detector material has been studied. The obtained results were compared with Monte Carlo and experimental published data to show the method's validity in the calibration process.Keywords
This publication has 15 references indexed in Scilit:
- Calibration of well-type NaI(Tl) detector using a point sources measured out the detector well at different axial distancesJournal of Instrumentation, 2015
- New numerical simulation approach to calibrate the NaI(Tl) detectors array using non-axial extended spherical sourcesJournal of Instrumentation, 2013
- Analytical expression to calculate total and full-energy peak efficiencies for cylindrical phoswich and lanthanum bromide scintillation detectorsRadiation Measurements, 2011
- Analytical calculations of the solid angles subtended by a well-type detector at point and extended circular sourcesApplied Radiation and Isotopes, 2006
- Efficiency calibration and coincidence summing correction for a 4π NaI(Tl) detector arrayNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Analytical formulae for well-type NaI (Tl) and HPGe detectors efficiency computationApplied Radiation and Isotopes, 2001
- A direct mathematical method to calculate the efficiencies of a parallelepiped detector for an arbitrarily positioned point sourceRadiation Physics and Chemistry, 2001
- Systematization of efficiency correction for gamma-ray disk sources with semiconductor detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Systematic treatment of the photopeak efficiencyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- Experimental and calculated photopeak e efficiency values for well-type NaI(Tl) detectorsThe International Journal of Applied Radiation and Isotopes, 1980