Sensitivity-Enhanced $LC$ Pressure Sensor for Wireless Bladder Pressure Monitoring
Authors:
- 25 February 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (12) , 4715-4724
Abstract
This paper presents a sensitivity-enhanced wireless passive LC pressure sensor for monitoring bladder pressure, which can be minimally invasive implanted in the bladder or integrated to a commercial urinary catheter and avoid battery lifetime problem. The proposed sensor design and the theoretical model are useful to increase the pressure sensitivity of a typical air-sealed capacitive pressure sensor, particularly having a flexible diaphragm. The test results of an in vitro evaluation of the prototype LC pressure sensor show a pressure sensitivity of 6385 ppm/kPa (a pressure responsivity of 1.215 MHz/kPa) before encapsulation coating in air at room temperature, whereas 4175 ppm/kPa (0.627 MHz/kPa) and 2679 ppm/kPa (0.304 MHz/kPa) after coating with silicone rubber in air and in water operation, respectively. Finally, the feasibility of the developed sensor is investigated through an animal test and confirmed by comparing with the data of conventional cystometry.Keywords
Funding Information
- Korea Health Industry Development Institute within the Ministry of Health and Welfare through the Korean Government (HI11C1017)
This publication has 28 references indexed in Scilit:
- Theoretical and experimental investigation of the trapped air effect on air-sealed capacitive pressure sensorSensors and Actuators A: Physical, 2015
- Fully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical StentIEEE Transactions on Biomedical Engineering, 2010
- Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure SensorsJournal of Microelectromechanical Systems, 2008
- Long term, implantable blood pressure monitoring systemsBiomedical Microdevices, 2007
- Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusionJournal of Vascular Surgery, 2007
- Permittivity measurements up to 30 GHz using micromachined probeJournal of Micromechanics and Microengineering, 2004
- Initial Animal Studies of a Wireless, Batteryless, MEMS Implant for Cardiovascular ApplicationsBiomedical Microdevices, 2004
- A self-resonant frequency-modulated micromachined passive pressure transensorIEEE Sensors Journal, 2003
- Dielectric Properties of Aqueous NaCl Solutions at Microwave FrequenciesThe Journal of Physical Chemistry A, 1997
- Analysis, Design, and Performance of a Capacitive Pressure Sensor ICIEEE Transactions on Biomedical Engineering, 1986