Maximizing precision and accuracy of the doubly labeled water method via optimal sampling protocol, calculation choices, and incorporation of 17O measurements
- 19 August 2019
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 74 (3) , 454-464
Abstract
Background/Objectives The doubly labeled water (DLW) method is the gold standard methodology for determination of free-living, total daily energy expenditure (TEE). However, there is no single accepted approach for either the sampling protocols (daily vs. two-point, in which samples are collected after dosing and at the end of the measurement period) or the calculations used in the determination of the rate of carbon dioxide production (rCO2) and TEE. Moreover, fluctuations in natural background abundances introduce error in the calculation of rCO2 and TEE. The advent of new technologies makes feasible the possibility of including additional isotope measures (17O) to account for background variation, which may improve accuracy. Subjects/Methods Sixteen subjects were studied for 7 consecutive days in a whole-room indirect calorimeter (IC) with concurrent measurement of TEE by DLW. Daily urine samples were obtained and isotope ratios were determined using off-axis integrated cavity output spectroscopy (OA-ICOS). Results We determined the best combination of approaches for estimating dilution spaces and elimination rates and calculated average daily volume of carbon dioxide production (VCO2) using six different published equations. Using this best combination, multi-point fitting of isotope elimination rates using the daily urine samples substantially improved the average precision (4.5% vs. 6.0%) and accuracy (−0.5% vs. −3.0%) compared with the two-point method. This improvement may partly reflect the less variable day-to-day chamber measurements of energy expenditure. Utilizing 17O measurements to correct for errors due to background isotope fluctuations provided additional but minor improvements in precision (4.2% vs. 4.5%) and accuracy (0.2% vs. 0.5%). Conclusions This work shows that optimizing sampling and calculation protocols can improve the accuracy and precision of DLW measurements.Keywords
Funding Information
- NIH Small Business Innovation (SBIR) Research Grant
- UK Royal society wolfson merit award Chinese government 1000 talents award
This publication has 24 references indexed in Scilit:
- Measurement of δ18O, δ17O, and 17O-excess in Water by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass SpectrometryAnalytical Chemistry, 2013
- Direct Analysis of δ2H and δ18O in Natural and Enriched Human Urine Using Laser-Based, Off-Axis Integrated Cavity Output SpectroscopyAnalytical Chemistry, 2012
- The role of technology in the past and future development of the doubly labelled water methodIsotopes in Environmental and Health Studies, 2005
- Comparison of Different Approaches for the Calculation of Energy Expenditure Using Doubly Labeled Water in a Small MammalPhysiological and Biochemical Zoology, 2005
- Measurements of 2H and 18O in body water: analytical considerations and physiological implicationsBritish Journal of Nutrition, 1994
- Doubly labelled water: Errors in the evaluation of oxygen isotope turnover due to temporal variation in CO2 production do not always covary with dilution space estimateJournal of Theoretical Biology, 1989
- The equilibrium concentration of oxygen-18 in body water: Implications for the accuracy of the doubly-labelled water technique and a potential new method of measuring RQ in free-living animalsJournal of Theoretical Biology, 1987
- Calculation of CO2 production in doubly-labelled water studiesJournal of Theoretical Biology, 1987
- Theory of use of the turnover rates of body water for measuring energy and material balanceJournal of Theoretical Biology, 1966
- New methods for calculating metabolic rate with special reference to protein metabolismThe Journal of Physiology, 1949