Outcomes of outflow graft stenting in HeartMate 3 left ventricular assist devices: A systematic review and individual patient data meta‐analysis
- 5 April 2024
- journal article
- review article
- Published by Wiley in Artificial Organs
- Vol. 48 (6) , 577-585
Abstract
Purpose: LVAD outflow graft stenosis continues to remain prevalent with a high complication rate. We sought to pool the existing evidence on indications, utilization patterns, and outcomes of transcatheter interventions for outflow graft stenosis in the HeartMate 3 LVAD.Methods: An electronic search was performed to identify all studies in the English literature reporting on HeartMate 3 LVAD outflow graft stenting. Patient‐level data were extracted for analysis.Results: Thirteen published reports and one unpublished case comprising a total of 28 patients were included. Median patient age was 68.5 years [Interquartile range: 58, 71] and 25.9% (7/27) were female. Dyspnea [60.7% (17/28)] was the most common presenting symptom. Low flow alarms were present in 60% (15/25) of patients. Findings included external compression [35.7% (10/28)], graft twist [21.4% (6/28)], graft twist and external compression [14.3% (4.28)], intraluminal thrombus [10.7% (3/28)], graft twist and intraluminal thrombus [3.6% (1/28)], and pseudoaneurysm of outflow graft [3.6% (1/28)]. Median time from LVAD implantation to stenting was 2.1 years [1.4, 3]. Immediate flow normalization after stenting was observed in 85.7% (24/28). The 30‐day mortality was 12% (3/25). Overall mortality was 12% (3/25) at a median follow‐up of 3.9 months [1, 17].Conclusion: Outflow graft stenting in the HeartMate 3 LVAD appears to be a reasonable treatment option for outflow graft stenosis, with low overall rates of complications and mortality. Further refinement of indications and approaches may improve outcomes.Keywords
This publication has 22 references indexed in Scilit:
- Cerebral protection during percutaneous intervention for left ventricular assist device outflow graft obstructionCatheterization and Cardiovascular Interventions, 2022
- Successful Percutaneous Treatment of Late Outflow Graft Failure of the Left Ventricular Assist Device: A Long-Term Follow-UpESC Heart Failure, 2021
- Outflow graft obstruction in patients with theHM3LVAD: A percutaneous approachCatheterization and Cardiovascular Interventions, 2021
- Primary results of long‐term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase: a study of 2200 HeartMate 3 left ventricular assist device implantsEuropean Journal of Heart Failure, 2021
- Outflow Graft Obstruction After Left Ventricular Assist Device Implantation: A Retrospective, Single-Centre Case SeriesESC Heart Failure, 2021
- An interventional approach to left ventricular assist device outflow graft obstructionCatheterization and Cardiovascular Interventions, 2021
- Extracorporeal Membrane Oxygenation-Assisted Emergency Percutaneous Treatment of Left Ventricular Assist Device Graft OcclusionESC Heart Failure, 2021
- Untwist the twist: instant hemodynamic improvement in known HeartMate 3 complicationJournal of Artificial Organs, 2020
- Percutaneous treatment of left ventricular assist device outflow graft obstructionCatheterization and Cardiovascular Interventions, 2020
- Survival outcomes of stenting outflow graft stenosis in continuous-flow left ventricular assist devices: a systematic reviewHeart Failure Reviews, 2019