Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque
Open Access
- 22 December 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (1) , 226-230
Abstract
In order to improve the performance of magnetic resonance imaging and spectroscopy of atherosclerotic plaque the potential use of novel radiofrequency coil structures with sensitive detection volumes tailored to the geometry of the arterial wall was investigated. It was found that a cylindrical meanderline (zig–zag) coil design provides a sensitive volume that is restricted to a cylindrical shell, thereby maximizing the filling factor and signal-to-noise ratio for plaques while reducing the intense blood signal. The cylindrical meanderline coil has the added advantages of an open interior, which allows for unimpeded blood flow during scanning, and the potential to be expanded against the walls of the artery, thereby stabilizing the coil against the pulsatile blood flow and minimizing motion artifacts. The performance of cylindrical meanderline coils with theoretical simulations of the electromagnetic fields as well as with experimental images of test objects (phantoms) and human endarterectomy surgical specimens is demonstrated. This radically new RF coil geometry offers the potential to improve the efficiency of MR data acquisition in medical applications in which curved surfaces or slabs contain the material of interest. Magn Reson Med 53:226–230, 2005.Keywords
This publication has 17 references indexed in Scilit:
- Reciprocity and sensitivity of opposed-solenoid endovascular MRI probesJournal of Magnetic Resonance, 2002
- Vascular stents as RF antennas for intravascular MR guidance and imagingMagnetic Resonance in Medicine, 1999
- Single-loop coil concepts for intravascular magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- Intravascular magnetic resonance imaging using a loopless catheter antennaMagnetic Resonance in Medicine, 1997
- A novel topical probe for MRI: The flat, truncated line probeMagnetic Resonance Imaging, 1995
- Prototype Miniature Endoluminal MR Imaging CatheterJournal of Vascular and Interventional Radiology, 1993
- Real‐time position monitoring of invasive devices using magnetic resonanceMagnetic Resonance in Medicine, 1993
- MR imaging of blood vessels with an intravascular coilJournal of Magnetic Resonance Imaging, 1992
- Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imagingMagnetic Resonance in Medicine, 1992
- In vivo 31P nuclear magnetic resonance measurements in canine heart using a catheter-coil.Circulation Research, 1984