We report on the comparative analysis of self-calibrating and single-slope diffuse reflectance spectroscopy in resistance to different measurement perturbations. We developed an experimental setup for diffuse reflectance spectroscopy (DRS) in a wide VIS-NIR range with a fiber-optic probe equipped with two source and two detection fibers capable of providing measurements employing both single- and dual-slope (self-calibrating) approaches. In order to fit the dynamic range of a spectrometer in the wavelength range of 460–1030 nm, different exposure times have been applied for short (2 mm) and long (4 mm) source-detector distances. The stability of the self-calibrating and traditional single-slope approaches to instrumental perturbations were compared in phantom and in vivo studies on human palm, including attenuations in individual channels, fiber curving, and introducing optical inhomogeneities in the probe–tissue interface. The self-calibrating approach demonstrated high resistance to instrumental perturbations introduced in the source and detection channels, while the single-slope approach showed resistance only to perturbations introduced into the source channels.Keywords
Funding Information
- Center of Excellence «Center of Photonics» (075-15-2022-316)
- the Ministry of Science and Higher Education of the Russian Federation (075-15-2022-316)
This publication has 49 references indexed in Scilit:
- Non-invasive evaluation of therapeutic response in keloid scar using diffuse reflectance spectroscopyBiomedical Optics Express, 2015
- Measuring tissue hemodynamics and oxygenation by continuous-wave functional near-infrared spectroscopy—how robust are the different calculation methods against movement artifacts?Physiological Measurement, 2014
- Experimental and analytical comparative study of optical coefficient of fresh and frozen rat tissuesJournal of Biomedical Optics, 2013
- Improved identification of peripheral lung tumors by using diffuse reflectance and fluorescence spectroscopyLung Cancer, 2013
- Optical sensing for tumor detection in the liverEuropean Journal of Surgical Oncology, 2013
- Diagnostic power of diffuse reflectance spectroscopy for targeted detection of breast lesions with microcalcificationsProceedings of the National Academy of Sciences, 2012
- Biomedical photoacoustic imagingInterface Focus, 2011
- Effect of bile absorption coefficients on the estimation of liver tissue optical properties and related implications in discriminating healthy and tumorous samplesBiomedical Optics Express, 2011
- Melanin absorption spectroscopy: new method for noninvasive skin investigation and melanoma detectionJournal of Biomedical Optics, 2008
- Photon migration in the presence of a single defect: a perturbation analysisApplied Optics, 1995