Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT): a comparative evaluation of VasoCT and intravascular OCT
- 14 July 2015
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 8 (8) , 847-852
Abstract
Background Poor vessel wall apposition of flow diverter (FD) stents poses risks for stroke-related complications when treating intracranial aneurysms, necessitating long-term surveillance imaging. To facilitate quantitative evaluation of deployed devices, a novel algorithm is presented that generates intuitive two-dimensional representations of wall apposition from either high-resolution contrast-enhanced cone-beam CT (VasoCT) or intravascular optical coherence tomography (OCT) images. Methods VasoCT and OCT images were obtained after FD implant (n=8 aneurysms) in an experimental sidewall aneurysm model in canines. Surface models of the vessel wall and FD device were extracted, and the distance between them was presented on a two-dimensional flattened map. Maps and cross-sections at potential locations of malapposition detected on VasoCT-based maps were compared. The performance of OCT-based apposition detection was evaluated on manually labeled cross-sections using logistic regression against a thresholded (≥0.25 mm) apposition measure. Results VasoCT and OCT acquisitions yielded similar Grading of Regional Apposition after Flow-Diverter Treatment (GRAFT) apposition maps. GRAFT maps from VasoCT highlighted 16 potential locations of malapposition, of which two were found to represent malapposed device struts. Logistic regression showed that OCT could detect malapposition with a sensitivity of 98% and a specificity of 81%. Conclusions GRAFT delivered quantitative and visually convenient representations of potential FD malapposition and occasional acute thrombus formation. A powerful combination for future neuroendovascular applications is foreseen with the superior resolution delivered by intravascular OCT.Keywords
This publication has 42 references indexed in Scilit:
- Target delineation for radiosurgery of a small brain arteriovenous malformation using high-resolution contrast-enhanced cone beam CTJournal of NeuroInterventional Surgery, 2013
- Automated tissue characterization of in vivo atherosclerotic plaques by intravascular optical coherence tomography imagesBiomedical Optics Express, 2013
- Automatic lumen segmentation in IVOCT images using binary morphological reconstructionBioMedical Engineering OnLine, 2013
- Automatic stent detection in intravascular OCT images using bagged decision treesBiomedical Optics Express, 2012
- Optical coherence tomography: from research to practiceEuropean Heart Journal - Cardiovascular Imaging, 2012
- Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomographyMedical Physics, 2011
- Frameless multimodal image guidance of localized convection-enhanced delivery of therapeutics in the brainJournal of NeuroInterventional Surgery, 2011
- Neuroendovascular Optical Coherence Tomography Imaging and Histological AnalysisNeurosurgery, 2011
- Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverageThe International Journal of Cardiovascular Imaging, 2011
- Stent implant follow-up in intravascular optical coherence tomography imagesThe International Journal of Cardiovascular Imaging, 2009