Performance of an Isolated Induction Generator Under Unbalanced Loads
- 15 December 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 25 (2) , 303-311
Abstract
In this paper, the performance of an isolated self-excited induction generator driven by a wind turbine under unbalanced loads is studied. First, the whole system, including the induction generator, the capacitors, and the loads, is modeled. The model used for the isolated induction generator is a diphase one obtained, using the Park transformation. This model allows the saturation effect to be taken into account, assuming certain simplifying hypotheses. Then, the developed model is validated comparing simulation and experiment results at no load and for balanced load cases. Finally, the same model is used to study the performance of the isolated induction generator under unbalanced load cases. Compared to the experiments, the simulation results show a good prediction of the electrical variable waveforms. Furthermore, it can be seen that the magnitude and frequency of the voltages do not vary a lot even if the load is hardly unbalanced.Keywords
This publication has 26 references indexed in Scilit:
- Control strategies for an autonomous induction generator taking the saturation effect into account2007
- Dynamic modeling and analysis of three phase self-excited induction generator using generalized state space approach2006
- Dynamic performances of self-excited induction generator feeding different static loadsSerbian Journal of Electrical Engineering, 2006
- Operation of induction generator in the magnetic saturation region as a self-excited and as a double output systemJournal of Materials Processing Technology, 2005
- State space modeling of parallel self-excited induction generators for wind farm simulation2004
- Performance evaluations of three-phase self-excited induction generator with variable-speed wind turbine and minimum required capacitance2004
- Transient performance of an isolated induction generator under unbalanced excitation capacitorsIEEE Transactions on Energy Conversion, 1999
- Impact of cross-saturation on accuracy of saturated induction machine modelsIEEE Transactions on Energy Conversion, 1997
- A unified approach to main flux saturation modelling in D-Q axis models of induction machinesIEEE Transactions on Energy Conversion, 1995
- Capacitance requirements of self-excited induction generatorsIEEE Transactions on Energy Conversion, 1993