Automatic Supported Liquid Extraction (SLE) Coupled with HILIC-MS/MS: An Application to Method Development and Validation of Erlotinib in Human Plasma
Open Access
- 1 April 2010
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 2 (2) , 105-118
Abstract
A novel bioanalytical method was developed and validated for the quantitative determination of erlotinib in human plasma by using the supported liquid extraction (SLE) sample cleanup coupled with hydrophilic interaction liquid chromatography and tandem mass spectrometric detection (HILIC-MS/MS). The SLE extract could be directly injected into the HILIC-MS/MS system for analysis without the solvent evaporation and reconstitution steps. Therefore, the method is simple and rapid. In the present method, erlotinib-d6 was used as the internal standard. The SLE extraction recovery was 101.3%. The validated linear curve range was 2 to 2,000 ng/mL based on a sample volume of 0.100-mL, with a linear correlation coefficient of > 0.999. The validation results demonstrated that the present method gave a satisfactory precision and accuracy: intra-day CV < 5.9% (<8.4% for the lower limit of quantitation, LLOQ) with n = 6 and the accuracy of 98.0–106.0%; inter-day CV < 3.2% (<1.5% for LLOQ) with n = 18 and the accuracy of 100.0–103.2%. A dilution factor of 10 with blank plasma was validated for partial volume analysis. The stability tests indicated that the erlotinib in human plasma is stable for three freeze-thaw cycles (100.0–104.5% of the nominal values), or 24-h ambient storage (100.0–104.8% of the nominal values), or 227-day frozen storage at both -20 ºC (91.5–94.5% of the nominal values) and -70 ºC (93.3–93.8% of the nominal values). The results also showed no significant matrix effect (<6.3%) even with direct injection of organic extract into the LC-MS/MS system. The validated method has been successfully applied to support a clinical study.Keywords
This publication has 28 references indexed in Scilit:
- Using supported liquid extraction together with cellobiohydrolase chiral stationary phases-based liquid chromatography with tandem mass spectrometry for enantioselective determination of acebutolol and its active metabolite diacetolol in spiked human plasmaJournal of Chromatography B, 2009
- An improved LC–ESI–MS–MS method for simultaneous quantitation of rosiglitazone and N-desmethyl rosiglitazone in human plasmaJournal of Pharmaceutical and Biomedical Analysis, 2008
- Historical review of sample preparation for chromatographic bioanalysis: pros and consDrug Development Research, 2007
- Fully automated liquid–liquid extraction for the determination of a novel insulin sensitizer in human plasma by heated nebulizer and turbo ionspray liquid chromatography-tandem mass spectrometryJournal of Chromatography B, 2005
- Automated 96-well liquid–liquid back extraction liquid chromatography–tandem mass spectrometry method for the determination of ABT-202 in human plasmaJournal of Pharmaceutical and Biomedical Analysis, 2004
- 96-Well liquid–liquid extraction liquid chromatography-tandem mass spectrometry method for the quantitative determination of ABT-578 in human blood samplesJournal of Chromatography B, 2004
- Semi-automated liquid–liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasmaJournal of Chromatography B, 2002
- A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96‐well diatomaceous earth plates for solid‐liquid extractionRapid Communications in Mass Spectrometry, 2002
- Enantiomeric separation and quantification of fluoxetine (Prozac®) in human plasma by liquid chromatography/tandem mass spectrometry using liquid‐liquid extraction in 96‐well plate formatRapid Communications in Mass Spectrometry, 2002
- Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin ) in human plasmaRapid Communications in Mass Spectrometry, 2000