Diabetes can cause dangerous complications if not diagnosed in a timely manner. The World Health Organization accepts glycated hemoglobin (HbA1c) as a measure of diagnosing diabetes as it provides significantly more information on the glycemic behavior from a single blood sample than the fasting blood sugar reading. The molar absorption coefficient of HbA1c is needed to quantify the amount of HbA1c present in a blood sample. In this study, we measured the molar absorption coefficient of HbA1c in the range of 450 nm to 700 nm using optical methods experimentally. We observed that the characteristic peaks of the molar absorption coefficient of HbA1c (at 545 nm and 579 nm for level 1, at 544 nm and 577 nm for level 2) are in close agreement with those reported in previous studies. The molar absorption coefficient values were also found to be close to those of earlier reports. The average molar absorption coefficient values of HbA1c were found to be at 545 nm and at 579 nm for level 1 as well as at 544 nm and at 577 nm for level 2. Our experiments focused on calculating the molar absorption coefficients of HbA1c in the visible wavelength region, and the proposed experimental method has an advantage of being able to easily obtain the molar absorption coefficient at any wavelength in the visible wavelength region. The results of this study are expected to help future investigations on noninvasive methods of estimating HbA1c levels.
Keywords
Funding Information
- National Research Foundation of Korea (2022R1A5A7000765)
- National Research Foundation of Korea (NRF-2022R1A2C2010298)
This publication has 23 references indexed in Scilit:
- Determination of glucose and Hba1c values in blood from human breath by using Radial Basis Function Neural Network via electronic nose2014
- Non-invasive wearable electrochemical sensors: a reviewTrends in Biotechnology, 2014
- Electrodeposition of nickel oxide and platinum nanoparticles on electrochemically reduced graphene oxide film as a nonenzymatic glucose sensorSensors and Actuators B: Chemical, 2014
- Absorption Spectroscopy for the Estimation of Glycated Hemoglobin (HbA1c) for the Diagnosis and Management of Diabetes Mellitus: A Pilot StudyPhotomedicine and Laser Surgery, 2013
- Recent advances in electrochemical glucose biosensors: a reviewRSC Advances, 2012
- International Expert Committee Report on the Role of the A1C Assay in the Diagnosis of DiabetesDiabetes Care, 2009
- Flexible Rolled Thick‐Film Miniaturized Flow‐Cell for Minimally Invasive Amperometric SensingElectroanalysis, 2008
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Noninvasive Glucose SensingAnalytical Chemistry, 2005
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987