Automated accurate mass data processing using a gas chromatograph/time‐of‐flight mass spectrometer in drug discovery
Authors:
Open Access
- 11 May 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (11) , 1492-1498
Abstract
A gas chromatograph/time‐of‐flight (GCT) mass spectrometer, with high mass measurement accuracy to within 5 ppm, has been used for the automated accurate mass analysis of multicomponent mixtures and drug discovery compounds. A multicomponent mixture was analyzed several times over the course of a week to assess the reproducibility and ruggedness of the automated method while operating the GCT in electron ionization mode. For example, the data for 31 radical cations generated via electron ionization was processed using automated software (i.e. OpenLynx™) to provide for mass accuracies less than 5 ppm for nearly 100% of the ions from multiple injection data. Mass accuracies of the radical anions of polyaromatic hydrocarbons generated via negative chemical ionization, and protonated pyridines and quinolines generated via methane chemical ionization, were mainly less than 5 ppm from multiple injection data. In addition, the automated method has been used for the accurate mass analysis of drug discovery compounds. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Open‐access high‐resolution mass spectrometry in early drug discoveryJournal of Mass Spectrometry, 2004
- Collision‐induced dissociation of valdecoxib metabolites: a novel rearrangement involving an isoxazole ringJournal of Mass Spectrometry, 2004
- A fully automated method for accurate mass determination using high‐performance liquid chromatography with a quadrupole/orthogonal acceleration time‐of‐flight mass spectrometerRapid Communications in Mass Spectrometry, 2004
- A comparison of accurate mass techniques for the structural elucidation of fluconazoleRapid Communications in Mass Spectrometry, 2003
- Exact mass measurement on an electrospray ionization time‐of‐flight mass spectrometer: error distribution and selective averagingJournal of Mass Spectrometry, 2003
- Investigations into the accuracy and precision obtainable on accurate mass measurements on a quadrupole orthogonal acceleration time‐of‐flight mass spectrometer using liquid chromatography as sample introductionRapid Communications in Mass Spectrometry, 2003
- The Automation of a Commercial Fourier Transform Mass Spectrometer to Provide a Quick and Robust Method for Determining Exact Mass for the Synthetic ChemistEuropean Journal of Mass Spectrometry, 2003
- An introduction to quadrupole–time‐of‐flight mass spectrometryJournal of Mass Spectrometry, 2001
- High-resolution LC/MS for analysis of minor components in complex mixtures: negative ion ESI for identification of impurities and degradation products of a novel oligosaccharide antibioticJournal of Mass Spectrometry, 2000
- Application of a new atmospheric pressure ionization source for double focusing sector instrumentsJournal of Chromatography A, 1995