Association between left ventricular lead position and intrinsic QRS morphology with regard to clinical outcome in cardiac resynchronization therapy for heart failure
Open Access
- 18 May 2023
- journal article
- research article
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 28 (4) , e13065
Abstract
Background: Left ventricular (LV) lead position may be an important factor for delivering effective cardiac resynchronization therapy (CRT). We therefore aimed to evaluate the effects of LV lead position, stratified by native QRS morphology, regarding the clinical outcome.Methods: A total of 1295 CRT‐implanted patients were retrospectively evaluated. LV lead position was classified as lateral, anterior, inferior, or apical, and was determined using the left and right anterior oblique X‐ray views. Kaplan Meier and Cox regression were performed to evaluate the effects on all‐cause mortality and heart failure hospitalization, and the potential interaction between LV lead position and native ECG morphologies.Results: A total of 1295 patients were included. Patients were aged 69 ± 7 years, 20% were female, 46% received a CRT‐Pacemaker (vs. CRT‐Defibrillator), mean LVEF was 25% ± 7%, and median follow‐up was 3.3 years [IQR 1.6–5–7 years]. Eight hundred and eighty‐two patients (68%) had a lateral LV lead location, 207 (16%) anterior, 155 (12%) apical, and 51 (4%) inferior. Patients with lateral LV lead position had larger QRS reduction (−13 ± 27 ms vs. −3 ± 24 ms, p < .001). Non‐lateral lead location was associated with a higher risk for all‐cause mortality (HR 1.34 [1.09–1.67], p = .007) and heart failure hospitalization (HR 1.25 [1.03–1.52], p = .03). This association was strongest for patients with native left or right bundle branch block, and not significant for patients with prior paced QRS or nonspecific intraventricular conduction delay.Conclusions: In patients treated with CRT, non‐lateral LV lead positions (including apical, anterior, and inferior positions) were associated with worse clinical outcome and less reduction of QRS duration. This association was strongest for patients with native LBBB or RBBB.Keywords
This publication has 25 references indexed in Scilit:
- Echocardiography-Guided Left Ventricular Lead Placement for Cardiac Resynchronization TherapyCirculation: Heart Failure, 2013
- Electrical and Mechanical Ventricular Activation During Left Bundle Branch Block and ResynchronizationJournal of Cardiovascular Translational Research, 2012
- Relationship between endocardial activation sequences defined by high-density mapping to early septal contraction (septal flash) in patients with left bundle branch block undergoing cardiac resynchronization therapyEP Europace, 2011
- Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) TrialCirculation, 2011
- Non-Responders to Cardiac Resynchronization Therapy - The Magnitude of the Problem and the Issues -Circulation Journal, 2011
- Impact of segmental left ventricle lead position on cardiac resynchronization therapy outcomesHeart Rhythm, 2010
- Effect of Posterolateral Scar Tissue on Clinical and Echocardiographic Improvement After Cardiac Resynchronization TherapyCirculation, 2006
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureNew England Journal of Medicine, 2005
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002