Comparison of N95 Disposable Filtering Facepiece Fits Using Bitrex Qualitative and TSI Portacount®Quantitative Fit Testing
Authors:
- Dale J. StephensonDSDale J. Stephenson
- David O. WallaceDWDavid O. Wallace
- Dean R. LillquistDLDean R. Lillquist
- Anthony J. SurudaASAnthony J. Suruda
- 1 January 2000
- journal article
- research article
- Published by Taylor & Francis in International Journal of Occupational and Environmental Health
- Vol. 6 (1) , 50-54
Abstract
As a means of evaluating the use of denatonium benzoate (bitrex) as a qualitative fit test agent with filtering facepiece respirators, the bitrex qualitative and TSI Protacount(R) quantitative fit-test methods were compared using N95 filtering facepieces. Seventy-nine paired tests (trial) were performed. Detection of bitrex during a qualitative fit test or measurement of a fit factor of <100 during a quantitative fit test constituted a failure. Qualitative and quantitative methods were performed using identical test protocols. Data were analyzed using pass/fail criteria, and matched-pair analysis methods were applied. The results of this study indicate that the use of bitrex during qualitative fit testing of N95 disposable filtering facepieces results in an increase in failure and/or rejection in cases where a TSI Portacount (plus N95 companion accessory) quantitatively establishes an acceptable fit.Keywords
This publication has 5 references indexed in Scilit:
- Field Performance Measurements of Half-Facepiece Respirators—Foundry OperationsAIHA Journal, 1996
- Development of a New Qualitative Test for Fit Testing RespiratorsAIHA Journal, 1995
- Variation in Quantitative Respirator Fit Factors Due to Fluctuations in Leak Size During Fit TestingAIHA Journal, 1994
- AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGESAIHA Journal, 1992
- Bittering agents in the prevention of accidental poisoning: children's reactions to denatonium benzoate (Bitrex).Emergency Medicine Journal, 1991