Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant‐Retained Overdentures
- 16 September 2015
- journal article
- Published by Wiley in Journal of Prosthodontics
- Vol. 25 (8) , 656-664
Abstract
Purpose: The aim of this in vitro study was to evaluate and compare mandibular denture base deformation between ball and Locator attachments of implant‐retained overdentures.Materials and Methods: An experimental acrylic model covered with resilient silicone mucosal simulation was constructed. Two laboratory implants were placed in the canine areas of the model. Two duplicate experimental overdentures were constructed and connected to the implants with either ball (GI) or Locator (GII) attachments. To measure overdenture strain around the attachments, 3 strain gauges were attached to the lingual polished surface of the overdentures opposite to the right implant (loading side) 2 mm above the attachment level (Ch1), at the attachment level (Ch2), and 2 mm below the attachment level (Ch3). Another 3 gauges were bonded opposite to the left implant (non‐loading side) in the same manner (Ch6, Ch7, and Ch8). To measure strain at the midline of the overdentures, two strain gauges were attached in the midline at 5 mm intervals (Ch4 and Ch5). A universal testing device was used to deliver vertical static load of 50 N unilaterally and bilaterally to the first molar area to measure strain using a multi‐channel digital strain meter.Results: During bilateral load application, GII recorded higher compressive strains than GI at the majority of channels. During unilateral load application, GI recorded higher tensile strains at Ch1, Ch2, and Ch3, and GII recorded higher strains than GI at Ch6, Ch7, and Ch8. During bilateral loading the highest strain was concentrated at Ch5 for both groups. During unilateral loading, the highest strain was concentrated at Ch2 for GI, and at Ch5 for GII.Conclusion: Ball attachments for implant‐retained overdentures were associated with significant mandibular denture base deformation over the implants compared to Locator attachments. Therefore, denture base reinforcement may be recommended with ball attachmentz to increase fracture resistance of the base.Keywords
This publication has 29 references indexed in Scilit:
- Clinical success of implant-supported and tooth–implant-supported double crown-retained denturesClinical Oral Investigations, 2011
- The Effect of Denture Cleansing Solutions on the Retention of Pink Locator Attachments: An in Vitro StudyJournal of Prosthodontics, 2010
- Attachment Systems for Implant Retained Overdentures: A Literature ReviewImplant Dentistry, 2006
- Surgical and prosthetic planning for a two-implant–retained mandibular overdenture: A clinical reportThe Journal of Prosthetic Dentistry, 2006
- The Role of Abutment‐Attachment Selection in Resolving Inadequate Interarch Distance: A Clinical ReportJournal of Prosthodontics, 2005
- A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year resultsThe Journal of Prosthetic Dentistry, 2005
- A prospective study of single stage surgery for implant supported overdenturesClinical Oral Implants Research, 2002
- Brånemark System® and ITI Dental Implant System® for treatment of mandibular edentulismClinical Oral Implants Research, 2001
- Fiber-reinforced composite framework for implant-supported overdenturesThe Journal of Prosthetic Dentistry, 2000
- Metal reinforcement for implant-supported mandibular overdenturesThe Journal of Prosthetic Dentistry, 2000