Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study
- 26 May 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (22) , 7833-7843
Abstract
A set of quality assurance/quality control (QA/QC) criteria for nontargeted measurement of pesticide exposure markers in a large-scale study of human urine has been proposed and applied across five laboratories within the HBM4EU project. Quality control material, including reference standards and fortified pooled urine samples (QC urine) were prepared in a centralized way and distributed across participants to monitor analytical performance and consistency of the liquid chromatography coupled to high-resolution mass spectrometry data generated with a harmonized workflow. Signal intensities, mass accuracy, and retention times of selected QA/QC markers covering a broad range of physicochemical properties were monitored across QC solvent standards, QC urine samples, study urine samples, and procedural blanks, setting acceptance thresholds for repeatability and accuracy. Overall, results showed high repeatability of the collected data. The RSDs of the signal intensities were typically below 20-30% in QC and study samples, with good stability of the chromatographic separation (retention time drift within 2-4 s intrabatch and 5 s interbatch) and excellent mass accuracy (average error < 2 ppm). The use of the proposed criteria allowed for the identification of handling errors, instrumental issues, and potential batch effects. This is the first elaboration of harmonized QA/QC criteria applied across multiple laboratories to assess the quality of data generated by nontargeted analysis of human samples.Keywords
Funding Information
- European Union?s Horizon 2020 research and innovation programme, HBM4EU Project (733032)
This publication has 27 references indexed in Scilit:
- Comprehensive analytical strategy for biomonitoring of pesticides in urine by liquid chromatography–orbitrap high resolution mass spectrometryJournal of Chromatography A, 2014
- Can we trust untargeted metabolomics? Results of the metabo-ring initiative, a large-scale, multi-instrument inter-laboratory studyMetabolomics, 2014
- Identifying Small Molecules via High Resolution Mass Spectrometry: Communicating ConfidenceEnvironmental Science & Technology, 2014
- Intra- and Interlaboratory Reproducibility of Ultra Performance Liquid Chromatography–Time-of-Flight Mass Spectrometry for Urinary Metabolic ProfilingAnalytical Chemistry, 2012
- MetAlign 3.0: performance enhancement by efficient use of advances in computer hardwareMetabolomics, 2011
- Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometryTalanta, 2011
- Global metabolic profiling procedures for urine using UPLC–MSNature Protocols, 2010
- LC–high resolution MS in environmental analysis: from target screening to the identification of unknownsAnalytical and Bioanalytical Chemistry, 2010
- MetAlign: Interface-Driven, Versatile Metabolomics Tool for Hyphenated Full-Scan Mass Spectrometry Data PreprocessingAnalytical Chemistry, 2009
- GerES IV Pilot Study: Assessment of the exposure of German children to organophosphorus and pyrethroid pesticidesInternational Journal of Hygiene and Environmental Health, 2006