Same-day versus first-day review of intraocular pressure after uneventful phacoemulsification
Authors:
- Paris G. TranosPTParis G. Tranos
- Sanjeewa S. WickremasingheSWSanjeewa S. Wickremasinghe
- Darius HildebrandDHDarius Hildebrand
- Riaz AsariaRARiaz Asaria
- Ali MearzaAMAli Mearza
- Seyed Ghazi-NouriSGSeyed Ghazi-Nouri
- Brian C. LittleBLBrian C. Little
- 1 March 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 29 (3) , 508-512
Abstract
To compare the incidence and the spectrum of postoperative complications detected when the intraocular pressure (IOP) is reviewed 4 to 6 hours or the day after uneventful phacoemulsification cataract extraction and intraocular lens (IOL) implantation. Royal Free Hospital, London, United Kingdom. The study cohort consisted of 141 patients who had uneventful phacoemulsification and IOL implantation under regional (peribulbar/topical) or general anesthesia. Postoperative evaluation of the patients was performed by an ophthalmologist using a standard form at 4 to 6 hours or 24 hours. The mean IOP at 4 to 6 hours and 24 hours was 22.85 mm Hg +/- 9.56 (SD) and 19.44 +/- 7.04 mm Hg, respectively. The IOP was more likely to be greater than 30 mm Hg when measured on the same day, resulting in a significantly higher intervention rate than on the first day (P =.037). The best corrected visual acuity was significantly better at 24 hours than at the same-day review (P <.001). There was no significant difference in the extent of anterior chamber activity, patient comfort, or state of the wound between the same- or next-day follow-up. All patients attended a follow-up appointment 3 weeks after surgery, had an IOP of 21 mm Hg or less, and were subsequently discharged. The results indicate that moderate IOP spikes (<40 mm Hg) can be left untreated if they are not associated with corneal edema or patient discomfort as they decline spontaneously. Before they are discharged, patients with compromised optic discs or predisposed to retinal or optic nerve pathology should be carefully evaluated the day after surgery to treat IOP elevations.Keywords
This publication has 15 references indexed in Scilit:
- Is the first post-operative day review necessary following uncomplicated phacoemulsification surgery?Eye, 2000
- National cataract surgery survey 1997-8: a report of the results of the clinical outcomesBritish Journal of Ophthalmology, 1999
- Complications of phacoemulsification on the first postoperative day: can follow-up be safely changed?Journal of Cataract & Refractive Surgery, 1999
- First day post-operative review following uncomplicated phacoemulsificationEye, 1998
- Intraocular pressure rise after phacoemulsification with posterior chamber lens implantation: effect of prophylactic medication, wound closure, and surgeon's experience.British Journal of Ophthalmology, 1995
- Is the first day postoperative review necessary after cataract extraction?British Journal of Ophthalmology, 1995
- Intraokularer Druckanstieg nach Kataraktextraktion - Einfluß von Operationstechnik, Operationserfahrung und medikamentöser Prophylaxe - Eine prospektive, randomisierte DoppelblindstudieKlinische Monatsblätter für Augenheilkunde, 1995
- Do patients like day case cataract surgery?British Journal of Ophthalmology, 1992
- Daycase cataract surgery.British Journal of Ophthalmology, 1991
- Extracapsular Cataract Extraction and Posterior Chamber Lens Implantation in Eyes With Preexisting GlaucomaArchives of Ophthalmology (1950), 1986