Quantifying the contrast of the human locus coeruleus in vivo at 7 Tesla MRI
Open Access
- 6 February 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (2) , e0209842
Abstract
The locus coeruleus is a small brainstem nucleus which contains neuromelanin cells and is involved in a number of cognitive functions such as attention, arousal and stress, as well as several neurological and psychiatric disorders. Locus coeruleus imaging in vivo is generally performed using a T1-weighted turbo spin echo MRI sequence at 3 Tesla (T). However, imaging at high magnetic field strength can increase the signal-to-noise ratio and offers the possibility of imaging at higher spatial resolution. Therefore, in the present study we explored the possibility of visualizing the locus coeruleus at 7T. To this end, twelve healthy volunteers participated in three scanning sessions: two with 3T MRI and one with 7T MRI. The volumes of the first 3T session were used to segment the locus coeruleus, whereas the volumes of the second 3T and the 7T session were used to quantify the contrast of the locus coeruleus with several reference regions across eight different structural sequences. The results indicate that several of the 7T sequences provide detectable contrast between the locus coeruleus and surrounding tissue. Of the tested sequences, a T1-weighted sequence with spectral presaturation inversion recovery (SPIR) seems the most promising method for visualizing the locus coeruleus at ultra-high field MRI. While there is insufficient evidence to prefer the 7T SPIR sequence over the 3T TSE sequence, the isotropic voxels at 7T are an important advantage when visualizing small structures such as the locus coeruleus.Keywords
Funding Information
- European Research Council (GA 283314-NOREPI)
This publication has 52 references indexed in Scilit:
- Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validationFrontiers in Neuroscience, 2013
- Feasibility of Using Ultra-High Field (7 T) MRI for Clinical Surgical TargetingPLOS ONE, 2012
- High-Field Imaging of Neurodegenerative DiseasesNeuroimaging Clinics Of North America, 2012
- Origin and reduction of motion and f0 artifacts in high resolution T2*-weighted magnetic resonance imaging: Application in Alzheimer's disease patientsNeuroImage, 2010
- In vivo mapping of the human locus coeruleusNeuroImage, 2009
- Reliability of MRI-derived cortical and subcortical morphometric measures: Effects of pulse sequence, voxel geometry, and parallel imagingNeuroImage, 2009
- Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1American Journal of Neuroradiology, 2008
- High-field MRI of brain cortical substructure based on signal phaseProceedings of the National Academy of Sciences of the United States of America, 2007
- LIPOPROTEIN PIGMENTS—THEIR RELATIONSHIP TO AGEING IN THE HUMAN NERVOUS SYSTEMBrain, 1974